ENGINE CONTROL SYSTEM (J08E)
4–1166
1.
Disconnect the differential pressure sensor connector.
2.
Use the electrical tester to measure the resistance between the
terminals of the differential pressure sensor.
NO
YES
4
Inspect the differential pressure sensor (exhaust gas pressure sensor) unit
SAPH16F010300904
Measurement
conditions
Tester connections
Standard values
Starter switch:
LOCK
Differential pres-
sure sensor con-
nector
VCC
–
GND
VOUT
–
GND
2
–
15 k
GND
VCC
SAPH16F010300905
GND
VOUT
SAPH16F010300906
Are the measurements within standard value?
Go
to
step
5.
Replace the differential pressure sensor
(exhaust gas pressure sensor).
Perform "After-inspection work" of INFOR-
MATION section.
Содержание 238
Страница 201: ...ENGINE CONTROL SYSTEM J08E 4 978 Harness disconnection or short circuit ...
Страница 215: ...ENGINE CONTROL SYSTEM J08E 4 992 Malfunction of sensor 2 Malfunction of engine ECU ...
Страница 301: ...ENGINE CONTROL SYSTEM J08E 4 1078 8 Estimated failure factors Malfunction of engine ECU ...
Страница 327: ...ENGINE CONTROL SYSTEM J08E 4 1104 EGR valve malfunction Clogged air intake system VNT controller malfunction ...