ENGINE CONTROL SYSTEM (J08E)
4–1174
1.
In the log you received check if
[EECU_REQUEST_START_MANUAL_REGEN] is present after
[EECU_REQUEST_START_AUTO_REGEN].
HINT
If there is an EECU_REQUEST_START_MANUAL_REGEN, the DPR
manual regeneration request has been emitted correctly from the
ECU, and it has been received correctly by the BCU.
NO
YES
1.
In the obtained log, check if
[EECU_REQUEST_EMERGENCY_STOP] is present after
[EECU_REQUEST_START_AUTO_REGEN].
HINT
If there is an EECU_REQUEST_EMERGENCY_STOP, the DPR out-
let temperature is abnormally high and regeneration has not been
completed.
NO
YES
5
Check burner system 2 [Hino-DX]
Yes
Event #
TR hours
Event
Flame temp
959
1262:38:05 EECU_REQUEST_START_AUTO_REGEN
260
960
1262:43:21
IGNITION_SUCCESS
241
961
1262:43:24 EECU_REQUEST_STOP_REGEN
337
963
1262:46:54 EECU_REQUEST_START_MANUAL_REGEN
630
964
1262:47:18
IGNITION_SUCCESS
510
965
1262:56:29 EECU_REQUEST_STOP_REGEN
911
Event log example
SAPH16F010300915
Did you find a response log
?
Go to step 6.
Go to step 8.
HINT
The DPR manual regeneration request signal
is not being transmitted correctly to the ECU
(the DPR button has not been pressed, or
failure of the electrical system of the DPR
button).
6
Check burner system 3 [Hino-DX]
Yes
Event #
TR hours
Event
Flame temp
741
1208:26:21 EECU_REQUEST_START_MANUAL_REGEN
104
742
1208:26:43
IGNITION_SUCCESS
104
743
1208:41:29
EECU_REQUEST_EMERGENCY_STOP
943
Event log example
SAPH16F010300916
Did you find a response log
?
Go to DTC P200C.
Go to step 7.
Содержание 238
Страница 201: ...ENGINE CONTROL SYSTEM J08E 4 978 Harness disconnection or short circuit ...
Страница 215: ...ENGINE CONTROL SYSTEM J08E 4 992 Malfunction of sensor 2 Malfunction of engine ECU ...
Страница 301: ...ENGINE CONTROL SYSTEM J08E 4 1078 8 Estimated failure factors Malfunction of engine ECU ...
Страница 327: ...ENGINE CONTROL SYSTEM J08E 4 1104 EGR valve malfunction Clogged air intake system VNT controller malfunction ...
Страница 709: ...DEF SCR SYSTEM DCU 5 143 8 Estimated failure factors DEF pump pressure sensor malfunction ...