INSPECTION PROCEDURE: P20B3
1.
Check the connection of the coolant cut off valve connector
(Looseness and poor contact).
NO
YES
1.
Set the starter switch to the "LOCK" position.
2.
Remove the connector of the coolant cut off valve.
3.
Use the electrical tester to measure the resistance between the
terminals of the coolant cut off valve.
NO
YES
1
Inspect the coolant cut off valve connector
Was any failure found?
Connect securely, repair if needed.
Go to step 2.
2
Inspect the coolant cut off valve unit
LDU
LDV
SAPH16F020400162
Measurement
conditions
Tester
connections
Standard values
Starter switch:
LOCK
Coolant cut off
valve connector
LDU
–
LDV
20
C {68
F}:
9.04
–
9.52
Do the measurements meet the standard value?
Go to step 3.
Replace the coolant cut off valve.
Perform "After-inspection work" of INFOR-
MATION section.