Accelerator model
Required drive bay action
Tesla V100 16 GB, nonredundant
fan mode
SFF drive blanks in bays:
2-1, 2-2, 2-3, 2-4
4-1, 4-2, 4-3, 4-4
Tesla V100 32 GB, nonredundant
or redundant fan mode
SFF thermal bezel blanks in bays:
1-3, 1-4, 2-1, 2-2, 2-3, 2-4
3-3, 3-4, 4-1, 4-2, 4-3, 4-4
InfiniBand adapter model
Required drive bay action
IB HDR100/EN 100 GB 1P
940QSFP56
IB HDR100/EN 100 GB 2P
940QSFP56
IB HDR/EN 200 GB 1P
940QSFP56
SFF thermal bezel blanks in bays:
1-3, 1-4, 2-1, 2-2, 2-3, 2-4
3-3, 3-4, 4-1, 4-2, 4-3, 4-4
Remove the server from the chassis
CAUTION:
To prevent improper cooling and thermal damage, do not operate the chassis unless all
bays are populated with a component or a blank.
CAUTION:
To avoid damage to the server or server blank:
• Always support the bottom of the server or server blank when removing it from the chassis.
• Do not use the release lever to carry the server or server blank.
Procedure
on page 23.
2.
Disconnect all peripheral cables from the server.
3.
Remove the server from the chassis:
a.
Loosen the thumbscrew.
b.
Open the release lever.
c.
Use the release lever to pull the server out of the chassis.
28
Operations