Installing the FlexibleLOM adapter
CAUTION:
The maximum inlet ambient temperature for most components installed in the system is
35°C (95°F). Some components, however, are subject to thermal limitations depending on the
chassis model and the fan configuration. There are some hardware configurations where it is
necessary to limit the number of drives installed in the chassis. For more information, see
.
Prerequisites
• Verify that the FlexibleLOM riser cage is installed in the server.
• Before installing this option, make sure that you have a T-10 and a T-15 Torx screwdrivers available.
Procedure
1.
2.
Disconnect all peripheral cables from the server.
3.
Remove the server from the chassis
on page 28.
4.
on page 30.
5.
Remove the FlexibleLOM riser cage
6.
Lay the FlexibleLOM riser cage on its side with the riser slots facing up to access the FlexibleLOM
slot.
7.
Remove the FlexibleLOM slot blank.
8.
Install the FlexibleLOM adapter. Make sure that the board is firmly seated in the slot.
Hardware options installation
65