Description
Chassis
Fan
configuration
Number of drives
supported by the
server
Maximum inlet
ambient temperature
0 to 6 drives
With mix of SFF and
NVMe drives:
Not supported
With SFF drives only:
22°C (71.6°F)
Apollo r2800
Gen10 Chassis
(24 SFF backplane
with SAS
expander)
Redundant and
nonredundant
0 to 24 drives
Not supported
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
22°C (71°F)
NVIDIA Tesla
V100 16 GB
GPU
Apollo r2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
5 to 6 drives
Not supported
5 to 6 drives
Not supported
0 to 4 drives
Not supported
Nonredundant
0 to 3 drives
22°C (71°F)
Redundant
Not supported
Apollo r2600
Gen10 Chassis
(24 SFF or 16 SFF
+ 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
Not supported
0 to 6 drives
Not supported
Apollo r2800
Gen10 Chassis
(24 SFF backplane
with SAS
expander)
Redundant and
nonredundant
0 to 24 drives
Not supported
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Nonredundant
0 to 8 drives
Not supported
Redundant
22°C (71°F)
Nonredundant
0 to 4 drives
22°C (71°F)
Table Continued
Specifications
155