a.
Connect each power cord to the server.
b.
Connect each power cord to the power source.
The installation is complete.
For more information on UEFI configurations, see the Hewlett Packard Enterprise website:
https://hpe.com/hpsc/swd/public
Storage controller options
The server supports the following storage controllers:
• For SATA drives only – Embedded HPE Smart Array S100i SR Gen10 Controller
• For SAS and SATA drives – HPE Smart Array type-p controller
The Smart Array type-p controller options are supported in the:
◦
◦
Three-slot secondary riser slot 2 and riser slot 3 transfer board
IMPORTANT:
The Apollo r2800 Gen10 Chassis with 16 NVMe drives does not support connection
to the embedded Smart Array S100i SR Gen10 Software RAID nor to a Smart Array type-p
controller.
Installing a Smart Array type-p controller in the primary riser cage
CAUTION:
The maximum inlet ambient temperature for most components installed in the system is
35°C (95°F). Some components, however, are subject to thermal limitations depending on the
chassis model and the fan configuration. There are some hardware configurations where it is
necessary to limit the number of drives installed in the chassis. For more information, see
.
Prerequisites
• Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
• If you are installing a Smart Array P-class Gen10 controller, an energy pack option is required. For
more information, see the chassis user guide on the Hewlett Packard Enterprise website (
www.hpe.com/info/Apollo2000-Gen10-docs
).
• Before you perform this procedure, perform the following steps:
1.
Back up data on the system.
2.
Close all applications.
3. Update the server firmware if it is not the latest revision
.
4.
Do one of the following:
78
Hardware options installation