PMX command set (API)
PMX
A4354-2.2
HBM: public
413
Measuring Channel Select
Choose channel selection for channels to be recorded
The channels to be recorded are selected with this
command. MCS cannot be used for selection during data
acquisition. In this case, the command is acknowledged
with a "?". The query command is also possible during
recording.
Syntax:
MCS p1,.., pxx (x)
Parameters:
p1,.., pxx 1,.., xx Channel selection
MCS 0 (x) selects all the existing channels
MCS (x) deselects all channels
Note
:
Channels 17, 18 and 19 are the internal time stamps. The
time stamp is a 6‐byte counter with a rate of approx.
153,640 Hz. Time channels 17, 18 and 19 do not appear
in commands PCS?/SPS?. Times do not have
subchannel realizations (SMS command).
The binary ("measurement") data have a length of 8
bytes, where the highest valued two bytes are zero.
Time data are always placed at the end of one measval
line.
There is an implicit connection between the Sample rate
group and the three time channels:
Channel 17: Sample rate group 0
Channel 18: Sample rate group 1
Channel 19: Sample rate group 2
Note:
The response depends on the SRB command. Have a
look at STF and NTP command too. The multi IO‐card
PX878 is not selectable here. It does not create measure
ment values.
MCS
Содержание PX401
Страница 1: ...Operating Manual English PMX...
Страница 104: ...Electrical connections PMX 104 A4354 2 2 HBM public PMX...
Страница 136: ...Startup 136 A4354 2 2 HBM public PMX This takes you to the device overview Now you can measure make settings and observe...
Страница 141: ...Startup PMX A4354 2 2 HBM public 141 Network settings...
Страница 238: ...Internal calculation channels 238 A4354 2 2 HBM public PMX Appendix Details of the glyphs in example A...
Страница 239: ...Internal calculation channels PMX A4354 2 2 HBM public 239...
Страница 241: ...Internal calculation channels PMX A4354 2 2 HBM public 241...
Страница 246: ...Internal calculation channels 246 A4354 2 2 HBM public PMX...
Страница 264: ...Internal calculation channels 264 A4354 2 2 HBM public PMX...
Страница 272: ...Parameter sets measurement programs 272 A4354 2 2 HBM public PMX...
Страница 295: ...Communication with a control system PMX A4354 2 2 HBM public 295...
Страница 297: ...Communication with a control system PMX A4354 2 2 HBM public 297...
Страница 300: ...Communication with a control system 300 A4354 2 2 HBM public PMX...
Страница 376: ...CODESYS V3 Soft PLC WGX001 only 376 A4354 2 2 HBM public PMX...
Страница 378: ...CODESYS V3 Soft PLC WGX001 only 378 A4354 2 2 HBM public PMX...
Страница 381: ...CODESYS V3 Soft PLC WGX001 only PMX A4354 2 2 HBM public 381...
Страница 392: ...CODESYS V3 Soft PLC WGX001 only 392 A4354 2 2 HBM public PMX Dialog Updating the PMX device...
Страница 489: ...Object directory PMX A4354 2 2 HBM public 489...
Страница 523: ...Diagnosis and maintenance PMX A4354 2 2 HBM public 523 Network settings...