USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Before you Begin
Overview
The procedure to install the OmniPL Retrofit Kit is as follows:
1.
Record Configuration, Settings and Timers Information:
Record all programming information on the enclosed worksheet.
2.
Record and identify all Wiring Connections:
Make sure that ALL circuit breakers are OFF prior to mainboard replacement and the unit power is discon-
nected. Remove the deadfront panel and identify all current wiring connections to the ProLogic, AquaLogic or AquaPlus mainboard. You’ll need to be familiar
with each connection to properly wire the new OmniPL mainboard.
3.
If using networked ColorLogic Lights:
Networked ColorLogic lights must be put into “Standalone” (default) mode before removing the current mainboard.
The OmniPL can only control ColorLogic lights in “Standalone” mode.
4.
Swap Mainboards, mount Controller and Program:
Remove all wiring connections to the mainboard. Remove the mainboard from the enclosure. Install
the new OmniPL mainboard. Mount Controller and connect all wiring to the OmniPL mainboard. Configure the OmniPL using all of the programming infor-
mation previously recorded on the worksheet (Configuration, Timers, and Settings menus). Check that all functions are operating properly.
OmniPL Controller
The Controller is weather resistant and comes with a 15 ft cord. Its resistive touchscreen with flip down cover is designed to function year round directly in
the elements. Because it plugs into the OmniPL mainboard, it should be mounted close by, but in a location that is convenient for the user to periodically view
and change pool/spa settings. Lastly, the Controller contains the Wifi radio and its location should be considered if planning to use a wireless connection to
the home router or access point. A wireless mobile device (phone, tablet, etc.) could be used to test the signal strength at the intended mounting location.
The Controller features a USB connector for firmware updates and logging feature as well as an Ethernet connector for optional direct wire connection to your
router (if wifi won’t or can’t be used).
What’s Included
Check that the following components have been included in your package:
• OmniPL Mainboard
• Controller
• 4 conductor transformer secondary cable
• 2 conductor transformer primary cable
• 2 conductor power input cable
Tools Needed
Phillips and flat screwdrivers
Wire cutters and strippers
Drill and drill bits for mounting Controller
Anchors and fasteners for mounting Controller
Record Configuration, Settings and Timer Information
Before installation, fill out the worksheets on page 2 and 3 by navigating through the various menu screens on your ProLogic, AquaLogic or AquaPlus. Most of
the information can be found within the Configuration Menu.
To access the Configuration Menu:
NOTE: The configuration menu automatically “locks” after 2 minutes of no buttons being pressed to prevent unauthorized people from changing the
control logic inadvertently and possibly damaging the pool equipment or causing a “call back” to fix the configuration.
Configuration
Menu-Unlocked
Configuration
Menu-Locked
Press repeatedly until “Configuration Menu” is displayed
Move to configuration menu items
Press BOTH buttons SIMULTANEOUSLY for 5 seconds to unlock