USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
16
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
If Yes is selected:
What Kind of Lights?
Touch the box to select the type of lights that will be used. The options are UCL (14V), CL4.0 (115V), CL2.5 (14V), P-Color,
Z-Color, Incandescent, and Other.
Name the Group of Lights
- Touch the box and use the keyboard to name the lights.
How Many Relays are Lights Wired to?
Select the number of relays used by the lights.
Which Relay is it Wired to?
Touching the box(es) will bring you to a table showing all detected relays. Select the relay(s) that are connected to
the lights and touch the Done button. The relay(s) should now be shown in the box(es) and you can advance to the next screen to continue the
configuration.
If UCL was previously selected:
Would you like to test for Omni Direct capability?
For UCL lights manufactured after June 2018, you can select Yes and the OmniPL
will test your lights to confirm. If your lights blink white after the test, you can enable Omni Direct mode. If not, the UCL light will default
to UCL Standalone mode. Refer to your Universal ColorLogic manual for more information about each mode.
How Many Accessories?
Select the number of accessories that will be used for this Body of Water only. You’ll have an opportunity to configure accessories
for the spa and also the backyard at a later point.
If “1”or more is selected:
Select and Configure Accessories
At this screen you can add, delete and configure your accessories. Select the desired accessory, then touch
the Advance button. When finished configuring accessories, you’ll be returned to this same screen. Touch the Done button and advance to the
next section of configuration. Refer to the following information when configuring accessories:
Type of Accessory?
Touch the box and select the type of accessory used. Choices are Laminars, Jets, Blower and Other.
Name of Accessory -
Touch the box and use the keyboard to name the accessory.
Does Accessory Have a Pump?
Select whether the accessory has a dedicated pump. If so, the OmniPL will turn this pump on when the ac-
cessory is scheduled to run.
If Yes is selected:
What Type?
Select the type of pump used. The choices are Single Speed, Two Speed and VSP.
If single speed or two speed pump is selected:
Which Relay is it Wired to?
If using a single speed or two speed pump, you’ll be asked which relay(s) is wired to the pump.
Select the proper relay(s) from the table and touch the Done button. The relay(s) should now be shown in the box(es) and you
can advance to the next screen to continue the pump configuration.
Would You Like to Enable Priming?
Select whether you want the pump to prime when turned on. This will turn the pump
on at high speed for 3 minutes to establish normal water flow every time the pump is activated after being off for at least 30
seconds. This option only appears if the pump is configured as a 2-Speed pump.
If VSP is selected:
Which Hayward Unique Address?
If using a VSP for your accessory pump, you’ll be asked what is the Hayward Unique
Address (HUA). If a value is already shown in the box, advance to the next screen. If no value is shown, selecting the box
will bring you to a table showing all detected devices. Select the proper HUA from the table and touch the Done button. The
address should now be shown in the box and you can advance to the next screen to continue the VSP configuration.
Pump Capacity -
Set the minimum and maximum RPM of the pump. Refer to your pump manual for more information.
Permitted User Setting -
The OmniPL will automatically calculate these values based on the minimum and maximum RPM
that were previously entered. They can be changed as desired.
Speed Presets -
Set the Low Pump Speed %, Medium Pump Speed %, and High Pump Speed %, presets. These presets
will be used when setting schedules for your pump.
Would You Like to Enable Priming?
Select whether you want the pump to prime when turned on. This will turn the pump
on at high speed for 3 minutes to establish normal water flow every time the pump is activated after being off for at least
30 seconds.
Accessory Wired to Relay?
Select whether the accessory requires the use of a high voltage relay.
If Yes is selected:
Select Relay -
Touching the box will bring you to a table showing all detected relays. Select the relay that is connected to the acces-