Hayward OmniPL HLXPROUPG Скачать руководство пользователя страница 17

15

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

the water feature is scheduled to run. 

If Yes is selected:

 

What Type?

 Select the type of pump used.  The choices are Single Speed, Two Speed and VSP. 

If single speed or two speed pump is selected:

 Which Relay is it Wired to?  

If using a single speed or two speed pump, you’ll be asked which relay(s) is wired to the pump. 

Selecting the box will bring you to a table showing all detected relays.  Select the proper relay(s) from the table and touch 

the Done. The relay(s) should now be shown in the box(es) and you can advance to the next screen to continue the pump 

configuration.

Would You Like to Enable Priming?  

Select whether you want the pump to prime when turned on.  This will turn the pump 

on at high speed for 3 minutes to establish normal water flow every time the pump is activated after being off for at least 30 

seconds.  This option only appears if the pump is configured as a 2-Speed pump.

If VSP is selected:

 

Which Hayward Unique Address? 

 If using a VSP for your water feature pump, you’ll be asked what is the Hayward Unique 

Address (HUA).  If a value is already shown in the box, advance to the next screen.  If no value is shown, selecting the box 

will bring you to a table showing all detected devices.  Select the proper HUA from the table and touch the Done button.  If 

unsure of the HUA, refer to the pump’s manual for instructions on how to determine the pump’s HUA. Once selected, the 

address should now be shown in the box and you can advance to the next screen to continue the VSP configuration.

 

Pump Capacity - 

Set the minimum and maximum RPM of the pump.  Refer to your pump manual for more information.

 

Permitted User Setting - 

The OmniPL will automatically calculate these values based on the minimum and maximum RPM 

that were previously entered.  They can be changed as desired. 

 

 

Speed Presets - 

Set the Low Pump Speed %, Medium Pump Speed %, and High Pump Speed %, presets.  These presets 

will be used when setting schedules for your pump.  

Would You Like to Enable Priming?  

Select whether you want the pump to prime when turned on.  This will turn the pump 

on at high speed for 3 minutes to establish normal water flow every time the pump is activated after being off for at least 

30 seconds.

Water Feature Wired to a Relay?

  Select whether the water feature requires the use of a high voltage relay.

If Yes is selected:

Select Relay - 

Touching the box will bring you to a table showing all detected relays.  Select the relay(s) that is connected to the water 

feature and touch the Done button.  The relay should now be shown in the box and you can advance to the next screen to continue 

water feature configuration.

Does Water Feature have a Valve? 

Select whether the water feature requires a valve to change position when in use. 

If Yes is selected: 

How Many? 

Select how many valves are used for the water feature.

Where is the Valve(s) Wired? 

Selecting the box will bring you to a table showing all detected low voltage relays.  Select the relay(s) 

that is wired to the water feature valve(s), then advance. The valve(s) should now be shown in the box.  Advance to the next screen to 

continue water feature configuration.

 

Freeze Protection Enabled?

 Freeze protection is used to protect the pool and plumbed equipment against freeze damage during cold tempera-

tures.  If freeze protection is enabled AND the air temperature falls below the freeze threshold (refer to pump configuration), the OmniPL will turn 

on the water feature pump to circulate the water.

If Yes is selected: 

 

Freeze Protect Speed? 

 This is the speed of the pump while freeze protection is active.  Select the desired pump speed %.  NOTE: 

this option only appears if the pump is a two speed pump or a variable speed pump.

Would You Like To Configure A Default Startup Speed For Water Feature?

 If the water feature has a valve and the system uses a VSP 

filter pump, the OmniPL allows you to set a startup pump speed for the water feature, regardless of the pump’s schedule. The speed will change 

at the next scheduled interval. 

Do You Want to Configure Any Lights?  

Select yes if you are using any type of pool or spa lights. The options are Universal ColorLogic (UCL), ColorLogic 

4.0 (CL4.0), ColorLogic 2.5 (CL2.5), Pentair Color LED (P-COLOR), Jandy Color LED (Z-Color), Incandescent, and Other. Transformers powering Universal 

ColorLogic lights must all be connected to the same high voltage relay for synchronization to function properly. If using Omni Direct mode, you must use an 

internal relay, not an HLRELAYBANK.

Содержание OmniPL HLXPROUPG

Страница 1: ...dustries 400 Connell Drive Suite 6100 Berkeley Heights NJ 07922 Phone 908 355 7995 www hayward com OmniPL Retrofit Kit Installation Manual HLXPROUPG Contents Before You Begin 1 Worksheet 2 Installation 4 Connection Table 7 Configuration 8 Automation and Chlorination ...

Страница 2: ...nstalled on the EcoStar pump if variable speed operation is desired with the OmniPL If single speed control is desired no changes are necessary NOTE If the control is using networked ColorLogic Lights the lights must be put into Standalone default mode before disconnecting the control The OmniPL can only control ColorLogic lights in Standalone mode FCC Statement This device complies with part 15 o...

Страница 3: ... in a location that is convenient for the user to periodically view and change pool spa settings Lastly the Controller contains the Wifi radio and its location should be considered if planning to use a wireless connection to the home router or access point A wireless mobile device phone tablet etc could be used to test the signal strength at the intended mounting location The Controller features a...

Страница 4: ...Function Manual On Off Timeclock Countdown Timer Solar Low Speed Interlock Enabled Disabled Freeze Protection Enabled Disabled Aux3 Config Function Manual On Off Timeclock Countdown Timer Solar Low Speed Interlock Enabled Disabled Freeze Protection Enabled Disabled Aux4 Config Function Manual On Off Timeclock Countdown Timer Solar Low Speed Interlock Enabled Disabled Freeze Protection Enabled Disa...

Страница 5: ...s _______to_______ Weekdays _______to_______ Aux2 All Days Weekends _______to_______ Weekdays _______to_______ Aux3 All Days Weekends _______to_______ Weekdays _______to_______ Aux4 All Days Weekends _______to_______ Weekdays _______to_______ Aux5 All Days Weekends _______to_______ Weekdays _______to_______ Aux6 All Days Weekends _______to_______ Weekdays _______to_______ Valve3 All Days Weekends ...

Страница 6: ...ecting the connector shown above Rectifier wiring These red black and orange wires must be removed from both ends mainboard and recti fiers and discarded This wiring will not be used with the OmniPL mainboard To maintain enclosure integrity do not remove rectifiers Input power wiring These black and white wires will be connected to Wago lever connectors on a wiring harness that plugs into the Omni...

Страница 7: ... supplied wiring harnesses using the colors as a reference for each connection blue to blue purple to purple etc The yellow secondary transformer leads will connect to the supplied wiring harness shown below The harness and the yellow transformer leads will need to be cut and stripped before inserting into the Wago lever connectors TurboCell connector is the same as old control Used for optional H...

Страница 8: ... page 26 To mount screw two appropriate fasteners into the mounting surface at the desired location as shown below Tighten until the bottom of the screw heads are 1 8 off the mounting surface Position the Con troller cutouts over the screw and slide the unit downward You may have to tighten or loosen the screws slightly to fully engage the screw heads to get a snug fit Run the Controller s 15 ft c...

Страница 9: ... the table below You ll be prompted to provide which pool equipment is connected to each Connection ID Because the control was previously wired take this time to go through each connection and fill out the table Refer to the graphic below for the physical location of these connections HVR1 HVR2 HVR3 HVR4 HVR5 HVR6 HVR7 HVR8 When using Optional Smart Relays ID ...

Страница 10: ...mniPL requires knowledge of all of the connected pool equipment so have the Connection Table page 7 handy while configuring the OmniPL If you are asked a question and don t know the answer in many cases you ll be able to skip the question and proceed In some cases the Configuration Wizard will require an answer Answer the question to the best of your ability and take note as you ll be able to go b...

Страница 11: ...ayed This unique number is used to identify your OmniPL when setting up a web account A web account is needed to access the OmniPL over the web by mobile devices IMPORTANT write down the MSP ID number for future use The MSP ID number will be needed when entering the configuration wizard after initial configuration as well as entering and exiting Simple Mode Simple Mode is a customizable screen tha...

Страница 12: ...ng If Yes is selected Freeze Protection Temperature Select the temperature to be used for freeze protection Temperature is adjustable from 33ºF 42ºF 1ºC 6ºC 38ºF 3ºC is default This threshold will be used for all outputs that have freeze protection enabled If VSP is selected Which Hayward Unique Address If using a VSP you ll be asked what is the Hayward Unique Address HUA If a value is already sho...

Страница 13: ...me will be used when referring to this particular heater Which Relay is it Wired to Selecting the box will bring you to a table showing all detected relays Select the low voltage relay that is wired to the heater refer to the Connection Table for this information then advance The relay should now be shown in the box Advance to the next screen to continue gas heater configuration If more than one h...

Страница 14: ...ets the demand within this time frame the next heater will not be used Minimum Operation Speed Select the lowest pump speed that is allowed while solar heating Set a speed that will ensure that there will be sufficient flow for the solar heating system to operate properly Would You Like To Prioritize The Use Of Solar Heating Over Any Other Types Select the lowest pump speed that is allowed while s...

Страница 15: ...Output The OmniPL can only generate chlorine while the filter pump is operating Set the percentage of run time that you desire chlorine generation Raise this value to generate more chlorine Lower this value to generate less Is pH Reduction Enabled Select Yes if you have a dispenser to lower pH connected to the OmniPL If Yes is selected Are you Using Acid or CO2 Select one How Many Acid CO2 Dispens...

Страница 16: ...to Enable Priming Select whether you want the pump to prime when turned on This will turn the pump on at high speed for 3 minutes to establish normal water flow every time the pump is activated after being off for at least 30 seconds Does Cleaner have a Valve Select whether the cleaner requires a valve to change position when in use If Yes is selected How Many Select how many valves are used for t...

Страница 17: ...mal water flow every time the pump is activated after being off for at least 30 seconds Water Feature Wired to a Relay Select whether the water feature requires the use of a high voltage relay If Yes is selected Select Relay Touching the box will bring you to a table showing all detected relays Select the relay s that is connected to the water feature and touch the Done button The relay should now...

Страница 18: ...cessory is scheduled to run If Yes is selected What Type Select the type of pump used The choices are Single Speed Two Speed and VSP If single speed or two speed pump is selected Which Relay is it Wired to If using a single speed or two speed pump you ll be asked which relay s is wired to the pump Select the proper relay s from the table and touch the Done button The relay s should now be shown in...

Страница 19: ... with Body of Water 1 If Yes is selected Your system will be fully shared which means your filter pump heaters chemistry will be shared between both Bodies of Water You can now set your filter pump and heater settings for this body of water If No is selected You will begin dual equipment setup for you second Body of Water This means that your filter pump and chemistry will not be shared between bo...

Страница 20: ...and you can advance to the next screen to continue configuration Do You Want to Configure Any Backyard Lights Select yes if you are using any type of pool spa or outdoor lights The options are Universal ColorLogic UCL ColorLogic 4 0 CL4 0 ColorLogic 2 5 CL2 5 Pentair Color LED P COLOR Jandy Color LED Z Color Incandescent and Other Transformers powering Universal ColorLogic lights must all be conne...

Страница 21: ...int For external inputs affected equipment will turn on off when the switch is actuated Advance through the configuration and when finished a summary screen will be displayed The summary will describe how the interlocked equipment will function Read through the description and make sure the equipment will function as desired If Equipment to Mode is selected With Equipment to Mode interlock affecte...

Страница 22: ...tem These buttons are as follows Save Touch this button to save the configuration edit This button only appears on the Quick Edit Home screen Cancel Touch this button to cancel any changes made to the configuration and exit Quick Edit This button only appears on the Quick Edit Home Screen Home Touch this button to quickly jump back to the Quick Edit Main Menu Screen to save your changes This butto...

Страница 23: ... want the Filter Pump to shut off while valves are turning Flow Monitoring Select whether you want flow to be monitored in this Body of Water Priming Select whether you want the Filter Pump to prime This option only appears if the FIlter Pump is configured as a 2 Speed or Variable Speed Pump Freeze Protect Select whether you want the Filter Pump to turn on for Freeze Protection Also set the Freeze...

Страница 24: ...blet feeder Dispenser Relay or Valve Depending on your dispenser type select the output that controls the dispenser ORP Timeout Choose the ORP timeout time and desired ORP setpoint This option is only available if ORP controls chlorination Delete Chem Sense Module Chlorination From this screen if you wish to delete any currently configured chemistry options select the trash can on the right of the...

Страница 25: ...ell as the Low Medium and High speed settings This option only appears if the water feature pump is configured as a Variable Speed Pump Priming Select whether you want the water feature pump to prime This option is only available if the water feature pump is config ured as a 2 Speed or Variable Speed Pump Freeze Protect Select whether you want the water feature to turn on for Freeze Protection Als...

Страница 26: ...e This is where you will be allowed to rename the Body of Water that you are currently configuring to whatever name you desire If Backyard is selected Select the Equipment that you would like to configure The options are Add Standalone Light and Add Accessory The configuration for these are described in the Configuration Wizard portion of this manual If Standalone Light is selected Add Standalone ...

Страница 27: ...f there are currently no interlocks configured on your system then the button will appear as Add Interlock instead of Interlocks In this case pressing Add Interlock will take you through the full configuration for adding a new interlock These steps are described in the Configuration Wizard por tion of this manual Once an interlock has been created the button will say Interlocks If System Options i...

Страница 28: ...To change functions or assign a new function select the button that you d like to configure If an Aux button is selected Select Function There are 4 options available Equipment Pressing this button will bring you to a screen that shows all available equipment Select the desired equipment that you want to assign to the Aux button Favorite Pressing this button will bring you to a screen that shows a...

Страница 29: ...st Hayward autho rized warranty service center For more information on authorized service centers please contact the Hayward Technical Service Support Center 61 Whitecap Road North Kingstown RI 02852 or visit the Hayward web site at www hayward com WARRANTY EXCLUSIONS 1 Material supplied or workmanship performed by others in process of installation 2 Damage resulting from improper installation inc...

Страница 30: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 28 ...

Страница 31: ...29 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS ...

Страница 32: ... Hayward Industries Inc 2021 Hayward Industries Inc All other trademarks not owned by Hayward are the property of their respective owners Hayward is not in any way affiliated with or endorsed by those third parties FOR FURTHER INFORMATION OR CONSUMER TECHNICAL SUPPORT VISIT OUR WEBSITE AT www hayward com ...

Отзывы: