USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
22
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Priority Duration - Select the number of hours that this heater will run before the next priority heater turns on.
Pump - Configure the boost pump for the heater. This option is only available if the heater is configured as a Solar heater.
Valve - Configure the heating valve, if used. This option is only available if the heater is configured as a Solar heater.
Solar Sensor - Configure the solar sensor. This option is only available if the heater is configured as a Solar heater.
Delete a Heater -
From this screen, if you wish to delete a heater that is currently configured, select the trash can on the right of the name
of the heater that you wish to delete.
If Chemistry is selected:
pH -
Once you select pH, all of the options for pH dispensing will appear on the next screen. These options are as follows:
Reduction ON - Select whether you want pH reduction to be enabled.
Chemical Type - Select the type of chemical that is being dispensed (acid or CO
2
).
pH Dispensers - Configure the pH dispense unit.
pH Timeout - Choose the pH timeout time.
pH Extend - Select whether you want pH extend enabled for this Body of Water.
Chem Sense Module -
Once you select Chem Sense Module, you will be able to select the HUA of your Chem Sense Module you are using
from the next screen.
Chlorination -
A flow switch must be installed for this function. Once you select Chlorination, all of the options for chlorination will appear
on the next screen. These options are as follows:
Dispenser Type - Select the type of dispenser used (T-CELL model, liquid chlorinator or tablet feeder).
Dispenser Relay or Valve - Depending on your dispenser type, select the output that controls the dispenser.
ORP Timeout - Choose the ORP timeout time and desired ORP setpoint. This option is only available if ORP controls chlorination.
Delete Chem Sense Module/Chlorination -
From this screen, if you wish to delete any currently configured chemistry options, select the
trash can on the right of the name of the item that you wish to delete.
NOTE: If either pH dispensing or chlorination are not configured, then this screen will give you the option to “Add CSM” or “Add Chlorination.”
If either of those options are selected, then you will be taken through the full configuration for that equipment as appears in the Configuration
Wizard portion of this manual.
If Cleaners is selected:
Add Cleaner -
Pressing “Add Cleaner” from this screen will take you through the full configuration for adding a new cleaner. These steps
are described in the Configuration Wizard portion of this manual.
Select a Cleaner -
Once you select a cleaner, all of the options for that cleaner will appear on the next screen. These options are as follows:
Name - Rename the cleaner to whatever name you desire.
Type - Select the type of cleaner that is configured (Pressure, Suction, Robotic, In Floor).
Pump - Configure the cleaner pump, if used.
Relay - Select the relay that the cleaner is wired to. This option only appears if the cleaner does not have an associated pump con-
figured.
Valve - Configure the cleaner valve, if used.
Freeze Protect - Select whether you want the cleaner to turn on for Freeze Protection. Also set the Freeze Protect air temperature
threshold from this menu.
Valve Cycle - Configure the valve cycling time period for the cleaner. This option is only available if the cleaner has an assigned valve.