If “1”or more is selected:
Name Filter Pump
- Touch the box and use the keyboard to name the filter pump.
What Type
- Depending on your answer, the OmniPL will use one relay (single speed pumps), two relays (two speed pumps) or the low speed
communication bus (VSP pumps) for pump control. Select the type of pump and advance.
If one speed or two speed pump is selected:
Which Relay is it Wired to?
If using a single speed or two speed pump, you’ll be asked which relay(s) is wired to the pump and a box
will be shown. Slecting the box will bring you to a table showing all detected relays. Select the proper relay(s) from the table and touch
the Done button to proceed. The relay(s) should now be shown in the box(es) and you can advance to the next screen to continue the
pump configuration.
Filter Pump Off for Valve Change?
When Yes is selected, the pump will shut off for 35 seconds whenever the valve(s) change posi-
tion.
Flow Monitoring Enabled?
Requires use of a Hayward flow switch. This feature will help protect the filter pump from damage due
to no flow. When Yes is selected, the OmniPL will monitor the state of water flow when the filter pump is on. If no flow is detected for
more than 20 minutes, the OmniPL will shut down the pool pump and will indicate an error. The error will be cleared the next time the
pump is turned on.
Would You Like to Enable Priming?
Select whether you want the filter pump to prime when turned on. This will turn the pump on at
high speed for 3 minutes to establish normal water flow every time the pump is activated after being off for at least 30 seconds. This
option only appears if the filter pump is configured as a 2-Speed pump.
Freeze Protection Enabled?
Freeze protection is used to protect the pool and plumbed equipment against freeze damage during cold
temperatures. If freeze protection is enabled AND the air temperature falls below the freeze threshold, the OmniPL will turn on the
filter pump to circulate the water. If two Bodies of Water are configured, the valves will also alternate between the pool and spa every
30 minutes and the filter pump will turn off while the valves are turning. The chlorinator will not operate if freeze protection is the only
reason the pump is running.
If Yes is selected:
Freeze Protection Temperature?
Select the temperature to be used for freeze protection. Temperature is adjustable from
33ºF-42ºF (1ºC-6ºC). 38ºF (3ºC) is default. This threshold will be used for all outputs that have freeze protection enabled.
If VSP is selected:
Which Hayward Unique Address?
If using a VSP, you’ll be asked what is the Hayward Unique Address (HUA). If a value is already
shown in the box, advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected
devices. Select the proper HUA from the table and touch the Done button. If unsure of the HUA, refer to the pump’s manual for instruc-
tions on how to determine the pump’s HUA. Once selected, the address should now be shown in the box and you can advance to the
next screen to continue the VSP configuration.
Pump Capacity -
Set the minimum and maximum RPM of the pump. Refer to your pump manual for more information.
Permitted User Setting -
The OmniPL will automatically calculate these values based on the minimum and maximum RPM that were
previously entered. They can be changed as desired.
Speed Presets -
Set the Low Pump Speed %, Medium Pump Speed %, and High Pump Speed %, presets. These presets will be used
when setting schedules for your pump.
Filter Pump Off for Valve Change?
When Yes is selected, the pump will shut off for 35 seconds whenever the valve(s) change posi-
tion.
Flow Monitoring Enabled?
Requires use of a Hayward flow switch. This feature will help protect the filter pump from damage due
to no flow. When Yes is selected, the OmniPL will monitor the state of water flow when the filter pump is on. If no flow is detected for
more than 15 minutes, the OmniPL will shut down the pool pump and will indicate an error. The error will be cleared the next time the
pump is turned on.
Would You Like to Enable Priming?
Select whether you want the filter pump to prime when turned on. This will turn the pump on
at high speed for 3 minutes to establish normal water flow every time the pump is activated after being off for at least 30 seconds.
Freeze Protection Enabled?
Freeze protection is used to protect the pool and plumbed equipment against freeze damage during cold
temperatures. If freeze protection is enabled AND the air temperature falls below the freeze threshold, the OmniPL will turn on the
filter pump to circulate the water. If two Bodies of Water are configured, the valves will also alternate between the pool and spa every