WARNING: Disconnect primary power prior to servicing.
Section 6 Diagnostics
Maxiva ULX COFDM Series
System
Power Fold-
back
The forward
power is folded
back (reduced) to
maintain the
reflected power
below 2.8% of
nominal power
(1.4:1 VSWR)
Trip point is set at
VSWR = 1.4:1.
This is a software
trip point which
depends on the
transmitter nomi-
nal power
WARNING
NO
NO
Reject 1
Fault
Reject power
threshold
exceeded
WARNING
NO
YES
YES
Reject 2
Fault
Reject power
threshold
exceeded
WARNING
NO
YES
YES
Reject 3
Fault
Reject power
threshold
exceeded
WARNING
NO
YES
YES
Table 6-4 Output Faults List
TYPE
Description
Fault Level or
Threshold
Transmitter
Action
Three
Strike
Available
in Life
Support
Содержание Maxiva ULX
Страница 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 296: ...B 20 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing Maxiva ULX COFDM Series ...