2-32
888-2629-200
10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
Maxiva ULX COFDM Series
2.8
Intercabinet Connections
For multi-cabinet transmitter models ULX-12800**, ULX-17000** and ULX-
24600**, the inter cabinet connections will need to be installed next. See Intercabinet
Wiring Diagram for reference.
2.9
External Interlock Connections
2.9.1
Interlock Connector on Customer I/O Panel
The interlock connector (12 pin) is located on the customer I/O panel at the top of the
transmitter. The WAGO style connector has contacts for up to four external interlocks.
Two are fault-off interlocks named System Safety Interlock and Cabinet Safety Inter-
lock. The other two are RF-mute interlocks named System RF Mute Interlock and Cabi-
net RF Mute Interlock. More interlocks may be incorporated by placing 2 or more
interlocks in series. The transmitter is shipped from the factory with jumpers in the
external interlock positions which will allow the transmitter to operate without external
interlock connections.
The Electrical Installation drawing shows that Interlock #1, J2-2 to J2-3, is used by a 3
Port Patch Panel or possibly a motorized switch. The External Interlock circuits requires
a closed connection on the following interlock connector terminals to allow the transmit-
ter to turn on:
•
J2 pins 2-3 System Safety Interlock (for 3 Port Patch Panel or switch)
•
J2 pins 5-6 System RF Mute Interlock (for load thermal interlock)
•
J2 pins 8-9 Cabinet Safety Interlock
•
J2 pins 11-12 Cabinet RF Mute Interlock
2.9.2
Fault-Off Interlocks (Safety Interlocks)
System Safety interlocks are Fault-Off interlocks and will shut the transmitter off if
opened. They are provided for use in protection of personnel. Cabinet Safety interlocks
are also Fault-Off interlocks and can be used in multi-cabinet transmitters to Fault-Off
individual PA cabinets. A manual turn on is required to recover from the Fault-Off
conditions caused by System or Cabinet Safety interlocks.
Содержание Maxiva ULX
Страница 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 296: ...B 20 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing Maxiva ULX COFDM Series ...