2-58
888-2629-200
10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
Maxiva ULX COFDM Series
•
J9 - Remote Analog Metering Outputs
NOTE:
The forward slash (/) in front of a signal name means active low. The signal
named "/INPUT 1" for example is activated by bringing that input low. Signal
names without the forward slash are considered active high. This convention is
used throughout the schematics.
2.15.1 Individual Transmitter Commands J3, J4 and J5
All control inputs use opto-isolators for surge protection. The opto-isolators are
powered by an in5Vdc from an isolation protection circuit.
All transmitter control functions (except Remote RF Mute, RF Switch Position A and
RF Switch Position B, which are active LOW or HIGH level input states) are
momentary ground switching and require the remote control equipment to sink at least
15mA to activate the function. The Pinouts of J3, J4 and J5 are listed in Table 2-12.
Table 2-12 J3, J4 & J5, Customer I/O Board, Remote Control Connectors
Connector
and pin #
Function
Command Type and
Polarity
J3-1
GROUND
J3-2
TRANSMITTER_ON
Pulsed LOW
J3-3
TRANSMITTER_OFF
Pulsed LOW
J3-4
RAISE_POWER
Pulsed LOW
J3-5
LOWER POWER
Pulsed LOW
J3-6
/RF_MUTE
J3-7
GROUND
J3-8
EXCITER_ A_SELECT
Pulsed LOW
J3-9
EXCITER_B_SELECTt
Pulsed LOW
J3-10
EXCITER_AUTO_SELECT
Pulsed LOW
J3-11
EXCITER_MANUAL_SELECT
Pulsed LOW
J3-12
GROUND
J4-1
GROUND
J4-2
IPA_A_SELECT
Pulsed LOW
J4-3
IPA_B_SELECT
Pulsed LOW
Содержание Maxiva ULX
Страница 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 296: ...B 20 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing Maxiva ULX COFDM Series ...