WARNING: Disconnect primary power prior to servicing.
Section 4 Theory of Operation
Maxiva ULX COFDM Series
•
2, 010, VSWR Fault
•
3, 011, Overdrive Fault
•
4, 100, PS Failure
•
5, 101, MOSFET Fault
•
6, 110, RF IN Low Fault
The Monitor board contains the PA module control circuitry. It is a CPLD controlled
circuit, which accepts commands from the TCU and returns status and monitoring
signals to the TCU. Within the PA module, the communication path between Monitor
board and the TCU is J1 on the Monitor board to J1 on the Signal Distribution board, J4
on the Signal distribution board to J2 on the Connector I/O board, and J2 to J1 on the
Connector I/O board. The Monitor board communicates with all of the other boards in
the PA module via its connectors J1, J2, and J4. Connector J3 on the Monitor board is a
test output used by engineering.
4.6.3.5
J1 - PA or IPA Connector I/O Board
Refer to Figure 4-16. The pins of sections A through D of the connector are in
horizontal rows of six pins, with pin 1 to the left and pin 6 shown to the right.
The pins of sections A through D are used for control, status, and monitoring.
Table 4-16 PA Module Front panel LED Indications
Index
LED Color
Indication
Description
1
Green
ON-OFF
ON: Green, OFF: None
2
Red
LDMOS Failure
When one or more LD-MOSEFET failed
3
Red
P.S. Failure
When one or more PS failed
4
Red
Temp Fault
When one or more Pallet temp fault
5
Red
VSWR Fault
Reflected Power Overload
6
Red
Power Overload
Input/Output Power Overdrive/ Overload
7
Green
Input Power OK
OK: Green; Input Power Low: Red
Содержание Maxiva ULX
Страница 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 296: ...B 20 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing Maxiva ULX COFDM Series ...