10/6/10
888-2629-200
5-25
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Maxiva ULX COFDM Series
5.9
PA Cabinet Fan Replacement
There are two 230V AC 50/60Hz fans in the Maxiva cabinet. They get their AC power
from the control breakers on power distribution panel.
NOTE:
Deactivating the control breakers will turn off the cabinet fans but they also will
disable the TCU and exciters.
The cabinet fans operate continuously whenever the transmitter is on. The fans are
redundant, either of the fans can be removed while the transmitter continues operating
with one remaining operational fan. The cabinet cooling fans supply air to the PA
modules, IPA (driver) modules and the predrivers. Exhaust air from the fans exits the
cabinet at the top.
5.9.1
Cabinet Fan Removal
STEP 1
Open the rear cabinet door.
STEP 2
Disconnect connectors J1 & J3 (see Figure 5-12) from the fan control
board which lies just above the fan that is to be removed.
Figure 5-12 Fan Control Board Connectors J1 & J3
STEP 3
Use a 10 mm socket driver to remove the two nuts (see Figure 5-13)
that hold the fan assembly in place.
REMOVE
Содержание Maxiva ULX
Страница 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 296: ...B 20 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing Maxiva ULX COFDM Series ...