5-48
888-2629-200
10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Maxiva ULX COFDM Series
Frequency
measurement
Agilent
53131A or 53181A
010 high stability time base
015 range extension to 1.5 GHz, OR
030 range extension to 3.0 GHz
Miscellaneous Test
Equipment
Bird
APM-16 wattmeter, with 1W to 1kW elements
Narda
Directional coupler
620-0457-000
Eagle
RLB-150 RF bridge
700-1289-000
Eagle
TNF-200 UHF RF notch filter
484-0300-000
Fluke
87 digital multimeter with 801-400 current probe
Optional
Adapters and
connectors
Myat
3-1/8 inch to 4-1/16 inch adaptor
620-2395-000
Dielectric
3-1/8 inch to 4-1/16 inch adaptor
620-1928-000
Myat
3-1/8 inch to 6-1/8 inch adaptor
620-2297-000
3-1/8 inch to type N adaptor
620-2859-000
Adapters and
connectors
Type N to BNC, male to female
620-0128-000
Type N to BNC, female to male
620-0547-000
BNC barrel, female to female
620-0604-000
BNC barrel, male to male
620-0564-000
SMA to BNC, male to female
620-2611-000
SMA to N, male to female
620-2562-000
SMB (push on) to BNC
620-0628-000
SMC to BNC, screw on jack to plug
620-2563-000
BNC to TNC, jack to plug
620-2821-000
BNC to TNC, jack to jack
620-2823-000
TNC to N, plug to jack
620-2824-000
TNC to N, jack to plug
620-2822-000
Attenuator
10 dB attenuator, type N, male to female
556-0074-000
Equipment Type
Manufacturer
Model Number
Options
Harris Part
No.
(if applicable)
TV Spectrum Analyzer
R&S
ETL
ETL-B203 RF pre-select.
FSL-B4 OCXO Ref. Freq.
FSL-B7 Nar. Res. Filters
ETL-K220 ATSC Demod.
DIV7 ETL-K208 Meas. Log
Demodulator
R&S
EFA
instead of ETL
Spectrum Analyzer
Agilent
4402
instead of ETL
Power measurement
Agilent
E44182B power meter with E9300B sensor, 100 uW to 3 W
Frequency
measurement
Agilent
53131A or 53181A
010 high stability time base
015 range extension to 1.5 GHz, OR
030 range extension to 3.0 GHz
Miscellaneous Test
Equipment
Bird
APM-16 wattmeter, with 1W to 1kW elements
Table 5-3 Recommended Test Equipment
Equipment Type
Manufacturer Model
Number
Options
Harris Part
No.
(if applicable)
Содержание Maxiva ULX
Страница 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 296: ...B 20 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing Maxiva ULX COFDM Series ...