4-36
888-2629-200
10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 4 Theory of Operation
Maxiva ULX COFDM Series
4.6.3.3
PA PS (AC/DC) Voltage Select Path
Each PA and IPA has eight AC/DC converters (power supplies) which supply voltage to
the drains each power amplifier FET. Depending on the RF frequency of operation, the
power supplies can be set for 44 Vdc, 46 Vdc, 48 Vdc or 50 Vdc. The power supply
output voltage select path, from the MCM board in the TCU to each power supply in
each PA and IPA module is shown in Figure 4-14 on page 4-37. The PA voltage select
path from the MCM board in the TCU to the IPA and PA backplanes, shown with bold
lines in figure Figure 4-14, is carried on pin 7 of the 25 conductor Cabinet Bus. This
represents the only use of the cabinet bus in the Maxiva transmitter.
Table 4-14 PS Connector Pin Assignments
Pin
Signal
Description
1
AC1
Input, 3.4A, 240VAC fused at 5A
2
NC
Not connected
3
AC2
Input, 3.4A, 240VAC fused at 5A
4
NC
5
NC
6
GND
Ground
7
GND
Ground
8
DC Trim
Input, 6.49K ohms, 0.75VDC to 6.0VDC
9
DC Source
Output, 0.4A, 50VDC
10
DC Sample
Output, 9.09 Ohm, 50VDC
Table 4-15 PA Module Power Supply Output Voltage Control
PA_Voltage_ Select Voltage
Power Supply Output Voltage
5.755 Vdc
44Vdc
4.122 Vdc
46 Vdc
2.490 Vdc
48 Vdc
0.875 Vdc
50 Vdc
Содержание Maxiva ULX
Страница 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 296: ...B 20 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing Maxiva ULX COFDM Series ...