WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
Maxiva ULX COFDM Series
The capacities shown in Table 2-3 include all cabinet components such as modules,
combiners and splitters. The values do not include the pump module coolant or the main
interconnection plumbing lines between the transmitter, pump module, and heat
exchanger. In multiple cabinet systems each cabinet will have it’s own pump module/
heat exchanger and associated plumbing.
The capacities shown in Table 2-4 include all components in the pump module/heat
exchanger unit. In multiple cabinet systems each cabinet will have it’s own pump
module/heat exchanger unit and associated plumbing.
To approximate the volume of interconnection plumbing line use Table 2-5 on page 2-
11 to determine the corresponding factor needed. Then multiply total of all line lengths
by factor to derive tubing volume. Add this volume to the corresponding volumes given
in Table 2-3 and Table 2-4 to determine approximate “Total” System Coolant Capacity.
Table 2-4
Heat Exchanger & Pump Module Capacities
Table 2-3
PA Cabinet Cooling Capacities
Transmitter Model
Approximate PA Cabinet Capacity
(less plumbing lines)
ULX-1100**
1.95 gallons (7.38 liters)
ULX-1700**
2.03 gallons (7.68 liters)
ULX-2300**
2.10 gallons (7.95 liters)
ULX-3400**
2.24 gallons (8.48 liters)
ULX-4400**
2.39 gallons (9.05 liters)
ULX-5500**
3.21 gallons (12.15liters)
ULX-6500**
3.35 gallons (12.68 liters)
ULX-8700**
3.64 gallons (13.78 liters)
Transmitter Model
Approximate PA Cabinet Capacity
(less plumbing lines)
2 Fan Unit
12.98 gallons (49.13 liters)
3 Fan Unit
16.09 gallons (60.91 liters)
Содержание Maxiva ULX
Страница 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 296: ...B 20 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing Maxiva ULX COFDM Series ...