WARNING: Disconnect primary power prior to servicing.
Section 4 Theory of Operation
Maxiva ULX COFDM Series
4.6.3.1
AC Distribution Board
The AC distribution board consists of three identical groups of AC line filtering, two
stages of transient protections per filter section. First stage of the protection is formed
by a network of MOVs which connects to the AC line filter inputs. The second stage of
protection provides a hard voltage limit by using high energy TVS devices, which are
connected at the output of each filter section. The maximum peak voltage is limited to
582Vpeak, and is below peak allowed voltage to AC/DC converter interface board.
On board 48V/12V DC/DC converter can provide up to 1.25A of continuous current.
Four wire WYE with neutral power system:
Four wire WYE configuration supports 380/400/415 Vac line to line voltages.
Converters are connected between line and neutral, which yields 220/230/240 Vac L-N.
Therefore, minimum Line-N voltage is 187Vrms.
Three wire Delta/WYE line to line power system:
Maxiva ULX power amplifier module employs a total of 8 power supply converters.
This presents an unbalanced load to the three phase power line grid.
4.6.3.2
AC/DC Converter Interface Board
AC/DC Converter Interface board is a 500W output AC to DC switching power supply.
It accepts universal AC input voltage from 85 to 265 Vac and the output voltage is
adjustable from 44V to 50Vdc. See section 4.6.3.3 on page 4-36 for additional
information on how PS voltages are set.
Converter is equipped with a power factor correction front end to reduce power line
harmonics. Because of the large DC reservoir capacitors connected to its DC bus, a step
start resistor is added to limit the inrush current to 7Apeak per converter, this is equal to
~1.5x converter’s maximum continuous operating current.
The AC/DC Converter Interface PWB is approximately 2.45” x 5.00”. All mounting
holes are electrically connected to ground. It is a 4 layers board. The AC/DC converter
boards are field replaceable. AC/DC converter (power supply) replacement instructions
can be found in section 5.7 on page 5-13.
Содержание Maxiva ULX
Страница 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 296: ...B 20 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing Maxiva ULX COFDM Series ...