Section 1 Introduction
Maxiva ULX COFDM Series
with the master TCU (in cabinet 1) are interrupted the
cabinet bus
allows each cabinet
to operate independently.
The heart of the control system is the TCU which is responsible for control, monitoring
and protection. The TCU contains the MCM (master controller module) which controls
all critical transmitter functions and the PCM (processor control module) which
provides enhanced monitoring and control, exciter and cabinet data collection, fault
logs and web remote connectivity. In addition to the MCM and PCM the Maxiva
COFDM main TCU contains six modular cards for the following sub-systems:
•
PA Interface -Provides interface between TCU, IPA (driver) and PA backplane
boards. The interface features 40 digital outputs/inputs and 24 analog outputs and
inputs. A fully populated cabinet will require two PA interface cards, one card per
eight PA modules. The PA interface card sends the ON/OFF commands to the PA
modules and receives fault information and status from them.
•
RF Detector/Pump Control/ Interlocks - Consists of a main board and a daughter
card. It features 7 RMS detectors with adjustable trip points (via EPOTS). It has
pump control and interlocks on one D25 pin connector.
•
Customer I/O - Provides parallel remote control, status and meter outputs. Connector
A has all inputs and Connector B has all outputs.
•
Exciter Switch - Contains PWB relay, 2 RMS detectors with adjustable trips (via
EPOTs) for power monitoring and a control/status interface for Exciters A and B.
•
PS Monitor - Monitors AC lines for phase imbalance and high or low voltage, cool-
ant inlet/outlet temperature, coolant flow, leaks, combiner temperature and cabinet
fans.
TCU’s also contain the following components:
•
Base-Plane - provides a common bus for custom plug-in cards
•
Power Supply Modules - two redundant internal power supply modules.
•
Standard Master Control Module (MCM) - FPGA based controller used for all criti-
cal transmitter control functions.
•
LED’s - standard front LED mimic display panel.
•
Processor Control Module (PCM) - Coldfire based micro module running embedded
Linux OS. It provides a touch screen for enhanced monitoring and control, exciter
and multi-cabinet data collection, fault logs and web remote connectivity.
•
Graphical User Interface (GUI) front panel - 5.25" color 1/4 VGA touch screen that
is present only in the main TCU (cabinet 1 in multi cabinet systems).
In multi-cabinet systems, there is a TCU in every cabinet. Each TCU will always
contain an MCM but PA cabinet TCU’s don’t require all TCU cards. The TCU in the
Содержание Maxiva ULX
Страница 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 296: ...B 20 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing Maxiva ULX COFDM Series ...