888-9058-001
WARNING: Disconnect and lockout AC primary power prior to servicing
95
3.16 Exciter Operation
3.16.1 Controls and Indicators
Refer to Figure 3-25 for the location of controls and indicators associated with day-to-day
standard operation of the HX-1V exciter. The function of each control and indicator is
listed in Table 3-4.
3.17 PA Cabinets
3.17.1 Circuit Breakers
Circuit breakers are located behind the lower panel of each amplifier cabinet.
CB-1: Logic breaker
CB-2: Fan breaker
3.17.2 Slave Controller
The slave controller is located in the upper left corner of each PA cabinet.
Refer to Figure 3-26.
3.17.2.1 Green Bar LED
Indicates AC power present to cabinet and controller, and +12 V supply is operating.
3.17.2.2 Red Bar LED
Summary fault indicator is illuminated when any one or more of the slave controller
faults in sensed. Opening the front panel reveals LED indicators for the various types of
faults.
3.17.2.3 Door Open
Rear cabinet door is open or SCR crowbar is firing.
3.17.2.4 Air Loss
Fan is not running, or air pressure is below the threshold of the air pressure sensing
switch.
3.17.2.5 PS-1 Fault
The power supply controller for 50 volt supply PS-1 has sensed a fault within the supply.
3.17.2.6 PS-2 Fault
The power supply controller for 50 volt supply PS-2 has sensed a fault within the supply.
3.17.2.7 Cabinet Select
In transmitters with multiple amplifier cabinets, this LED should blink indicating the
monitor board has accessed the slave controller