HARRIS
888-9058-001
WARNING: Disconnect and lockout AC primary power prior to servicing
116
•
Cabinet Communication Faults
•
Cooling, low air flow/pressure
•
Door Interlock, rear door open
•
External Interlock, usually used for hybrid reject load interlock
•
50 Volt Power Supply Fault
The green fault information turns red when the fault is active. Buttons across the bottom
allow cabinet selection. The Cab ID shows the slave controller ID for the cabinet selected
by the Cab ID select buttons.
Figure 4-13 P.A. Tab, Meter Button
Another screen to meter each PA cabinet output power, cabinet reflected power, drive
Power, voltage, and current of each 50 volt supply.
The top row of buttons select the cabinet in multiple PA systems. The bottom row
(above the page tabs) select the function to be metered.
The power supply button goes to the same screen that is available from the power supply
tab.