Figure 4-30 System TAB, Service Screen
The “Configure” column is used to select the model number of the transmitter. The “RF
On Delay” column is used to adjust the RF power reduction time length used during the
turn on cycle. The “Channel Number” is user selected. “External Interlock” selects a
choice of transmitter functions following an external interlock open-and-restore cycle.
Auto Restart turns the transmitter back on following an opening and re-closure of the
external interlock. The manual selection requires an operator ON command to restart the
transmitter. Auto restart is the normal mode, unless safety regulations require manual
restart.
“Revision” is the board and software information.
“Service” allows the capture of a snapshot of the transmitter data at that point in time.
This is functional only on the transmitter GUI screen and is grayed out on other screens.