WARNING: Disconnect and lockout AC primary power prior to servicing
41
2.6 Tap Transformers
The two (optional four) power supplies in the control cabinet, the supply with each slave
controller in the PA cabinets, and the 50 volt power supplies should be tapped for the
correct line voltage. It will be easier to re-tap the 50 volt supplies before installation. See
the following drawings:
•
Wiring Diagram for Control cabinet: 843-5583-001
•
Wiring Diagram for 50 Volt Supplies: 839-8106-235
•
Wiring Diagram for PA cabinet: Check the cover sheet in your drawing package
as different models of transmitters will contain more than one schematic.
2.7 Installation of 50 Volt Supplies
Half of the power supplies have the primary connected as DELTA loads, the others as
WYE loads. Each PA cabinet should have PS1 wired as a DELTA unit and PS2 should be
WYE connected. Check the serial numbers with the factory test data and install each supply
in the same location as it was tested. The 50 volt power supply weigh about 450 pounds
(205 kg). Use a mechanical lifting device to remove them from the skid. Two access holes
in the top are provided to attach lifting eyes to the transformer. Use a spreader bar to
prevent bending the lifting eyes.
NOTE:
The center of gravity is close to in line with lifting eye bolt holes.
The power supplies are furnished with two metal wheels for easy movement and
installation in the transmitter. Roll one supply into the cabinet, allowing room for the other
supply. The terminal boards should face the rear of the cabinet. After both supplies are
positioned, install the rear panel and feed the cables through the holes and up to the
terminal board. Each supply should be centered in its slot and tight against the panel. This
forms an air seal needed to maintain proper air flow throughout the cabinet.
WARNING:
REVERSING THE 50 VOLT SUPPLY POLARITY WILL DAMAGE THE PA MODULES
Use hardware as supplied with washers (1-split, 1-flat) to connect the two cables marked
(+) to left side of the 50 V bus bar, and two cables (-) to the right side.
2.8 RF Output Coax
WARNING:
WHEN INSTALLING RF PLUMBING OR AIR SYSTEM WIRING, DO NOT STEP ON THE TOP
OF THE DOORS OR THE CONNECTORS ON TOP OF THE PA CABINETS. LEAVE THE
PROTECTIVE COVER IN PLACE THAT PROTECTS THE I/O ON TOP OF THE CONTROL
CABINET.