WARNING: Disconnect and lockout AC primary power prior to servicing
58
STEP 2:
Verify the RF level, 40 to 60mW.
STEP 3:
Connect the 20 dB pad to the reflected input, connect the cable to the pad.
STEP 4:
Use the service screen to calibrate the reflected power metering to read
one percent of the forward power.
STEP 5:
Remove the pad and reconnect the cable.
2.17.2.3 PA Cabinet Power Calibration
The sample elements have coupling ratios marked on the element. These can be used as
offset inputs to the power meter. The slave controller calibrate pot is adjusted for 3 volts
at the peak detector test point. Next use the PA service button to access and set the PA
power levels.
2.17.2.4 Two Cabinet Reject Load
The power in the reject load is half of a single cabinet with perfect hybrids. If the level
measured at the top of the control cabinet is in the 40 to 60 mW range, calibrate the
reject load to be 80 percent of the reject load rating.
2.17.2.5 Three and Four Cabinet Calibration
Using the tables below calibrate the reject loads. Data is in cabinet power percentages.
CABINET
CABINET
CABINET
A/B
AB/C
COMBINED
A
B
C REJECT REJECT
OUTPUT
100
0
0
50
16.6
33.3
0
100
0
50
16.6
33.3
0
0
100
0
66.6
33.3
100
100
0
0
66.6
133.3
100
0
100
50
16.6
133.3
100
100
100
0
0
300
Figure 2-1
Three Cabinets
CABINETS
A/B
CABINETS
C/D
AB/CD
COMBINED
A & B
REJECT
C & D
REJECT
REJECT
OUTPUT
ONE
50
BOTH
0
25
225
BOTH
0
ONE
50
25
225
BOTH
0
NONE
0
100
100
ONE
50
ONE
50
0
100
BOTH
0
BOTH
0
0
400
Figure 2-2 Four Cabinets