______________________________________________
HARRIS
888-9058-001
WARNING: Disconnect and lockout AC primary power prior to servicing
45
2.14 Remote Control I/O:
Three "D" connectors for parallel remote control interface:
•
J31 Command in
•
J32 Status out
•
J33 Analog out
•
J34 Optional Exciter Switcher
(Refer to Control Cabinet Wiring Diagram.)
2.14.1 Command In
The Command inputs are all opto-coupled and require a current source to energize the
LED. This can be done either within the transmitter or externally. The Controller board
internal voltage source can be activated with JP2 jumper placed in the 1-2 position, which
will 5 volts from the internal supply for the optocouplers. If JP2 is placed in the 2-
3 position the optocouplers must be supplied a voltage on pins 19 & 37 of J31. The
optocouplers require a minimum current of 5 mA, and the maximum current should be less
than 20 mA.
Open circuit voltage with the internal source (JP2 1-2) is +5 volts. Any external source
(JP2 2-3) should be less than 36 volts.
2.14.1.1 J31 COMMAND INPUTS:
1:
TRANSMITTER ON
2:
TRANSMITTER OFF
3:
POWER RAISE
4:
POWER LOWER
5:
NO CONNECTION
6:
NO CONNECTION
7:
SELECT EXCITER A (OPT)
8:
SELECT EXCITER B (OPT)
9: SELECT MANUAL EXCITER SWITCHER MODE (OPT)
10:
SELECT AUTO EXCITER SWITCHER MODE (OPT)
11:
NO CONNECTION
12-18: NO CONNECTION
20-36: GROUNDS
19, 37: (OPT +5V J2 1-2) OR USE EXTERNAL SUPPLY (J2 2-3)