HARRIS
888-9058-001
WARNING: Disconnect and lockout AC primary power prior to servicing
54
water. The positive pressure inside the cabinet may be measured by temporarily removing a
mounting screw from one of the cover plates on the top rear of the cabinet.
STEP 7:
Check that all modules are enabled, PA modules will illuminate the left
half of the green LED. The right half will illuminate when drive is present. Modules in the
drive chain will illuminate full green even when no drive is present. It is normal for the red
module LED's to come on momentarily as the transmitter 50 volt supplies come up to
voltage at turn on. They also will come on at shut-down, gradually fading out as
the supplies discharge.
STEP 8:
Check MODULE FAULT status for each module. Check to see that all modules
are enabled (1/2 green LED on); press transmitter ON to enable any modules that are not
already on.
STEP 9:
Squeeze the disable switch in the handle of the first module. The module LED's
should go out. You should see the MODULE FAULT indication using the GUI screen, and
a module fault in the alarms queue. Re-enable the module by pressing transmitter ON at the
control cabinet. The MODULE FAULT on the control cabinet should go out. DELETE the
alarm from the queue. Repeat for each module in turn.
2.16 Initial Application of RF Power
2.16.1 Initial Application of RF Visual Power
STEP 1:
Check to insure the AGC module is OFF.
STEP 2:
LOWER the exciter to minimum drive.
STEP 3:
Press transmitter ON push-button.
STEP 4:
Check to see that all RF amplifier modules are enabled.
STEP 5:
Slowly raise power while observing VSWR and FORWARD POWER. However,
in a multiple PA cabinet system also observe the REJECT POWER(s). Stop at
approximately 25% forward power. Check to be certain the combined output at each hybrid
in a multiple PA system is higher than the reject load for the hybrid. If any reject load
power is higher than the hybrid's output, this suggests a phase error in drive cabling. Check
that drive cable connections are correct and the correct length. Verify the hard line lengths
follow the installation guidelines.
STEP 6:
Phase and Gain module alignment: A single cabinet transmitter will not
have any phase and gain units, A two PA system has one phase and gain module, the
procedure is performed only once. In a 3 PA systems, perform this sequence on the lower
level (A / B) phase and gain module, then proceed to the top level ([A+B] / C) module. In 4