WARNING: Disconnect and lockout AC primary power prior to servicing
46
The functions marked (OPT) are used when the optional exciter switcher is installed.
Command Functions:
TRANSMITTER ON: Turns transmitter on and enables RF output.
TRANSMITTER OFF: Turns transmitter off and disables RF output.
RAISE/LOWER: Raises or lowers the transmitter output power.
SELECT EXCITER (OPT): Selects exciter "A" or "B" via the optional exciter switcher.
SELECT MANUAL/AUTO (OPT): Selects the mode of operation for the exciter
switcher. MANUAL mode requires that the selection be done manually. When in
AUTO mode, if an exciter failure is detected, the switcher will automatically switch to
the alternate exciter if not in a foldback or muted state.
2.14.1.2 J32: Status Outputs
The Status outputs are N-Channel enhancement mode FETs with a 10 Ohm resistor in
series and a 30 volt zener (avalanche) diode clamp to ground. An internal voltage
source of +5volts can be made available to the outputs by placing main controller
optional status jumper JP3 in the 1-2 position. When in the 2-3 position, an external
voltage source must be supplied. The open collector stand-off voltage is 30 volts DC,
and maximum current sink is 50 ma. Each output is asserted low for status true
condition.
J32 STATUS OUTPUTS:
1-16: OPTIONAL VOLTAGE OUTPUT
(See information above)
17-18: NOT USED
19: OPTIONAL STATUS VOLTAGE INPUT
20: TRANSMITTER ON
21: LOCAL
22: VSWR FOLDBACK ACTIVE
23: VSWR FAULT
24: SPARE 1
25: SPARE 2
26: EXTERNAL INTERLOCK
27: AC POWER PHASE LOSS