Chapter 4 Device Configuring Using the Front Panel
Routing and Descrambling
© 2012 Harmonic Inc.
49
ProView 7000 v.2.6, Rev. E
❑
CAM 2
❑
CAM 3
12
❑
CAM 4
❑
None
■
Redundancy Triggers
❑
Sync Loss – Enable or disable, default is
Enable.
❑
CC Errors – Enable or disable, default is
Enable.
❑
PID Missing – Enable or disable, default is
Enable.
❑
Thresholds
• Sync Loss
· Primary Duration – set the period that the state must exist to trigger redundancy
· Backup Duration – set the period that the state must exist to trigger redundancy
• CC Errors
· Primary Duration – set the period that the number of CC errors must occur within
to trigger redundancy
· Primary Counter – set the number of CC errors that must occur within a period to
trigger redundancy
· Backup Duration – set the period that the number of CC errors must occur within to
trigger redundancy
· Backup Counter – set the number of CC errors that must occur within a period to
trigger redundancy
• PID Missing
· PID– set the PID number
· Primary Duration – set the period that the PID must be missing for to trigger
redundancy
· Backup Duration – set the period that the PID must be missing for to trigger
redundancy
■
Input Type
– Use this menu to select the input type
MPEG
or
DVB
.
12. ProView 7100™