Chapter 7 Device Configuring Using EMS
Physical Input Ports and Slots
© 2012 Harmonic Inc.
79
ProView 7000 v.2.6, Rev. E
■
Carrier Frequency
properties – Radio buttons selection, therefore only one is selected at a
time. Changing the value on one option, changes the other one automatically:
❑
L-Band Frequency Range
– Sets the L-Band frequency of the receiver local oscillator.
Range: 950,000 – 2,150,000 (in kHz), adjustable in 125 kHz steps.
❑
Frequency for the band selected in LNB
– Sets the frequency of the satellite, according
to the satellite transmitting frequency, adjustable in .125 kHz steps.
■
LNB
(Low Noise Block) Properties:
❑
Polarization
– Antenna polarization. Options:
• 13V (Vertical)
• 18V (Horizontal)
• Off
❑
LNB Frequency Band
– The default is Universal. Options:
• Universal (9.75, 10.6)
• Universal Wide (9.75, 10.75)
• Ku
• C
❑
LNB Local Oscillator Frequency (kHz)
–
For Universal and Universal Wide satellite frequencies, the LNB Local Oscillator
Frequency is set according to the 22 kHz Tone setting.
For K
u
band, adjustable, in the 8.5 GHz – 13 GHz range, in 125 kHz steps.
For C band, adjustable, in the 5 GHz – 6 GHz range, in 125 kHz steps.
❑
22 kHz Tone
–
Low Band
or
High Band
selectable for Universal and Universal Wide
satellite frequencies (not applicable for K
u
band and C band frequencies and not
displayed when K
u
or C band are selected)