Instructions for Hydronic systems (continued)
This unit must be wired by a qualified electrician
in accordance with the National Electrical Code.
Using a new 24 volt transformer, a new 24 volt relay, and a low voltage wall thermostat
the following wiring diagram shows how to modify the existing boiler aqua stat wiring.
By adding a normal open circuit into the existing aqua stat wiring you can leave the
boiler aqua stat set at the original factory setting. Set the new low voltage wall
thermostat approximately 3 degrees below the wood heat thermostat. If the heater
were to get behind for any reason the boiler can come on and help maintain the
building temperature.
EXISTING
BOILER
AQUASTAT
7
1
5
6
3
4
2
8
24 VOLT
TRA NSFORMER
NEUTRA L
120 VOLT
40 VA
THERMOSTA T
NEW ROOM
W
R
Wiring to add Hardy Hydronic Heater
to existing hydronic heating system.