HARDY MANUFACTURING CO., INC (MODEL LC300, LC500 & LC2500)
PAGE 43
8-1
GENERAL TROUBLE SHOOTING GUIDE (continued)
COMPLAINT
AREA OF TROUBLE
POSSIBLE CAUSE
CORRECTIVE ACTION
Improper
Burning
Grates
Grates stopped up
Clear grate of ash
buildup. If grates are
warped, turn over.
Air intake
Damper blower
clogged
Clean damper blower
assembly.
Air tube inspection
lid
Air tube clogged
Lift inspection lid and
cleanout all obstructions.
Smoke Stack
Smoke stack
stopped up
Remove smoke stack,
check flue out of top of
heater, clean both flue
pipe and smoke stack.
Baffle
(Model LC500 Only)
Baffle stopped up
Remove baffle through
the fire box door, clean
baffle and flue area.
Fire
Fire going out
If fire goes completely out
remove one screw in
blower lid.
Forced air blower
running but no draft
1. Solenoid not
lifting lid
2. Creosote buildup
1. Replace solenoid.
2. See excessive wood
usage.
Fire box
Moisture In
fire box
1. Initial or yearly
start up
2. Green wood
1. Fire box walls will
sweat and water will
run down sides, this
should clear up in
about a week.
2. Green wood will
create moisture at any
time.