HARDY MANUFACTURING CO., INC (MODEL LC300, LC500 & LC2500)
PAGE 45
8-2
Circulator Maintenance Instructions (continued)
Step #
Operation Description
Visual Aids/Comments
Testing Pump Capacitor
1
Remove top cover to expose electrical connections.
2
If using an analog ohm meter, check the resistance
across the two capacitor leads. The meter should
immediately read "0" ohms then slowly drift to infinity.
Reverse the test leads and check meter reading. The
test procedure is the same for a digital multimeter
except the meter will show some resistance then return
to "OL" (open line). To replace capacitor, cut away
existing wire nut connectors. Strip leads and connect
with wire nut connector suitable for two(2) 16 AWG
wires.
3
Replace cover.
Testing Pump Motor Winding
1
Disconnect power cord from motor wiring. Using an
ohm meter or continuity tester, check the continuity
across each power wire and also check each power
wire to ground. If the the pump does not show continuity
across the two power wires or if either power wire
shows continuity to ground the winding is defective and
the pump should be replaced.
!
Hazardous Voltage! Disconnect Power to
Heater prior to performing this
maintenance operation.