If you removed the hull to aid in plumbing the back of the heater it is time to place the
hull back on the heater. The space between the smoke stack ring and outside cover
will need a bead of silicone applied to fill any openings. The condenser tank will also
need to be sealed in this manner. The application of silicone to these openings is
illustrated by the diagram and pictures below. After these steps, you can install the
smoke stack. The trim should slide down the smoke stack until it sits on the outside
cover. The condenser stack must also be installed in the condenser tank opening. The
trim should slide down the condenser stack until it sits on the outside cover. You
should have a piece of insulation and a stainless steel plate that you removed from the
inside of the firebox earlier. This will install between the firebox door and the ash door.
The insulation fits between the doors and the stainless steel plate will slide behind the
door frames across the outer hull.
Do not seal the condenser tank to the condenser tank stack. This is the water
tank vent and must not be sealed.
3-6
Replacing Hull
Do not fill past
this point.
Smoke Stack and
Collar.
Seal perimeter of Smoke Stack ring
to Heater Hull using Silicone Sealant.
Seal perimeter of Condenser tank
ring to Heater Hull using Silicone
Sealant.
Do not seal Condenser Stack
To Condenser Tank.
Condenser Stack
and Collar.
Smoke stack ring
Condenser tank