HARDY MANUFACTURING CO., INC (MODEL LC300, LC500 & LC2500)
PAGE 39
Corrective Action
Possible Cause
Complaint
Area of Trouble
8-1
GENERAL TROUBLE SHOOTING GUIDE (continued)
Aqua stat
Defective Aqua stat Unplug power cord.
Connect the two wires on
the aqua stat together.
Plug in power cord. If
blower and damper
solenoid operates, replace
aqua stat.
No Heat
Main power
supply and
ground fault
interrupter
receptacle
“OK”
Water
temperature is
“COLD”
Forced air draft
blower motor
Defective blower
motor
1. Defective
electrical wiring
2. Air passage
stoppage
3. Blower wheel
clogged
1. Make sure all
connections are
secure.
2. Clear air passages in
cleanout and damper
blower outlets.
3. Clear blower wheel of
any lint, ashes or
creosote buildup.
Ash bin
Ash buildup in ash
bin
Clean out ash bin. Ash
bin should be cleaned out
each week. Ash buildup
on grates can cause
grates to warp. If grates
warp they can be turned
over and allowed to
straighten. When
removing ashes, leave at
least 1” of ashes in
bottom of ash pan.
Heater stack
Ash and creosote
buildup
Clean heater stack of
any ash and creosote
buildup. On LC500
models make sure the
baffle plate is clear of
ash and creosote
buildup. Make sure
baffle is in place,
otherwise heat will be
Defective damper
solenoid
Damper solenoid
When bypassing aqua
stat, if solenoid does not
lift the lid off the intake to
the forced air draft blower,
replace the solenoid.