(MODEL LC300, LC500 & LC2500)
ix
OUTDOOR WOOD HEATER BEST BURN PRACTICES
1.
1. Read and follow all operating instructions supplied by the manufacturer.
2. FUEL USED: Only those listed fuels recommended by the manufacturer of your unit.
Never use the following: trash, plastics, gasoline, rubber, naphtha, household
garbage, material treated with petroleum products (particle board, railroad ties and
pressure treated wood), leaves, paper products, and cardboard.
3. LOADING FUEL: For a more efficient burn, pay careful attention to loading times and
amounts. Follow the manufacturer’s written instructions for recommended loading
times and amounts.
4. STARTERS: Do not use lighter fluids, gasoline, or chemicals.
5. LOCATION: It is recommended that the unit be located with due consideration to the
prevailing wind direction.
6. Always remember to comply with all applicable state and local codes.
Outdoor Furnace Manufacturers Caucus
• Furnace should be located no less than 100 feet from any building not served by
the furnace.
• If located within 100 feet to 300 feet to any building not served by the furnace, it
is recommended that the stack be at least 2 feet higher than the peak of that
building.
Chimney Height Installation Scenario
Building
served by furnace
Building not
served by furnace
Chimney height
should be 2 feet above roof line.
2 feet
Minimum of 100 feet