HARDY MANUFACTURING CO., INC (MODEL LC300, LC500 & LC2500)
PAGE 47
8-4
Low Water Switch Replacement Instructions
Step #
Operation Description
Visual Aids/Comments
1
Open the tank drain valves until the water level is below
the float switch.
2
Remove plastic wire tie located near float switch. Cut
the switch wires approx. 6 inches from the rear of the
the float switch. On models with the automatic water fill
option do not cut the power wires for the solenoid.
Using an adjustable wrench or other suitable tool
remove the float switch from the heater.
3
Looking at the wrench flats on the switch there are two
directional arrows located on the side as shown. For
the switch to operate correctly it will have to be oriented
with the arrow pointed down when installed.
4
Apply pipe joint compound liberally around the threads
of the switch. Using an adjustable wrench or other
suitable tool install the switch in the tank. Do not
overtighten. Make sure the switch is oriented with the
arrow pointing down.
Arrow
Open these valves
Remove plastic
w ire tie.
Cut w ires approx. 6"
from rear of
switch.
!
Hazardous Voltage! Disconnect Power to
Heater prior to performing this
maintenance operation.