HARDY MANUFACTURING CO., INC (MODEL LC300, LC500 & LC2500)
PAGE 48
8-4
Low Water Switch Replacement Instructions (continued)
Step #
Operation Description
Visual Aids/Comments
5
Connect new switch wiring to existing wiring using
suitable wire nut.
6
Reconnect power to furnace. On models with the
automatic water fill option allow the unit to fill above the
float switch. If the automatic water fill and low water
indicator mounted on side of hull does not turn off when
the water reaches the correct level, the switch is
possibly not oriented correctly. On units without the
automatic water fill option, fill the tank until the water
level is above the float switch. The low water light
mounted on the left side of the hull should turn off when
the water is at this level. If the light does not go out the
switch is possibly oriented incorrectly.
!
Hazardous Voltage! Disconnect Power to
Heater prior to performing this
maintenance operation.