HARDY MANUFACTURING CO., INC (MODEL LC300, LC500 & LC2500)
PAGE 40
Water supply
Defective Liquid
Level Switch.
Liquid level switch
controls the water level
indicator light and water
solenoid valve. Check
switch with hand by
raising or lowering float
inside the condenser
area. If water solenoid
does not click and light
does not go on and off,
replace the liquid level
switch.
No Heat
Water Level is
“LOW”
Water
temperature is
“HOT”
Main power
supply and
Ground Fault
Interrupter
Receptacle
“OK”
Water solenoid
valve
1. Defective
solenoid valve
2. Water filter
1. If water solenoid valve
does not click when
checking the liquid
level switch, but level
indicator light does
come on – replace
solenoid valve.
2. Remove filter screen
from 1/2” bushing in
end of 1/2” ball valve,
clean or replace.
8-1
GENERAL TROUBLE SHOOTING GUIDE (continued)
Corrective Action
Possible Cause
Complaint
Area of Trouble
Содержание LC300