490, rue de l'Argon 

Québec  (Québec) G2N 2C9 

Phone: 418-849-8095     Fax : 418-849-0077 

www.jaroby.com 

 

 
 

 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

                        

 

 
 
 

 
 
 
 
 
 
 
 

September 7th, 2007 Review 

ATFM

Certified and tested according to 
CAN/CSA B366-1-M91 norms 

Содержание ATFM

Страница 1: ...490 rue de l Argon Qu bec Qu bec G2N 2C9 Phone 418 849 8095 Fax 418 849 0077 www jaroby com September 7th 2007 Review ATFM Certified and tested according to CAN CSA B366 1 M91 norms...

Страница 2: ...VERTICAL INSTALLATION 11 CLEARANCES 12 INSTALLATION OF THE FIREBRICKS 13 FANS AND THERMODISC 14 INSTALLATION OF THE 460 CFM FAN AND THE PROTECTION BOX 15 PROPULSION MODE 15 INSTALLATION OF THE 2 EXIT...

Страница 3: ...QUALIFY CERTIFIED TECHNICIAN AND IN CONFORMITY WITH THE OWNER S MANUAL GUIDE GIVEN WITH THIS APPLIANCE THE INSTALLATION MUST BE IN AGREEMENT WITH LOCAL AND NATIONAL REGULATIONS APPLICABLE FOR SOLID F...

Страница 4: ...4cm Dimensions Exterior height 42 in 107 95cm Exterior width 27 in 69 85cm Exterior depth 38 in 97 79cm Door openning 16 in X 10 in 40 64cm X 26 67cm Inside height 12 in 30 48cm Inside width 19 in 48...

Страница 5: ...a minimum of 64 ft2 and must be very well ventilated Minimum clearances found in this manual must be observed Never use a non isolated exterior conduct or a single wall flue pipe as an exterior exit P...

Страница 6: ...e knowledge of the procedure to be followed in case of a chimney fire Think of an emergency plan In case of a chimney fire Hermetically close the doors and the air intakes Water the combustible materi...

Страница 7: ...light smoke is released from the paint during the first hours of use Even if this nuisance is temporary open the windows and the doors in order to ensure a good ventilation This special paint is conce...

Страница 8: ...oss with an insulated lining The chimney has to be installed with a stainless steel lining Make sure that all smoke pipe joints are really airtight A leak reduces the efficiency of the appliance and c...

Страница 9: ...cal laws or the CAN CSA B365 ULC S635 ULC S640 UL 1777 norms Install the chimney following the manufacturer s instructions EXTERIOR VERTICAL INSTALLATION The ATFM wood appliance must be installed in a...

Страница 10: ...applicable local laws or the CAN CSA B365 norm Install the chimney following the manufacturer s instructions CROSS STYLE INSTALLATION The ATFM wood appliance must be installed in accordance with the...

Страница 11: ...11 VERTICAL INSTALLATION The ATFM wood appliance must be installed in accordance with the applicable local laws or the CAN CSA B365 norm Install the chimney following the manufacturer s instructions...

Страница 12: ...complete your decoration by its originality and its heat This appliance only needs a 12 inches clearance at its back and 12 inches from the lateral walls For the heat exchanger the clearances of zero...

Страница 13: ...install the side wall bricks 3 Install the back ones 4 Then install three pipes 2 and 3 and fix them 5 Install the two plates retaining the wool 6 Slide the bricks to be placed under the wool and to...

Страница 14: ...he fans When the appliance is in fonction and that the protection thermodisc fixed on the ventilation conduct reaches a temperature of 1600 F the thermodisc will stop the fans and will close the air e...

Страница 15: ...al box on the side 2 screws Position the rod allowing the air intake into the hole 2 Remove the panel recovering the two square holes Fix the 460CFM fan on the appliance with the 4 bolts rings and nut...

Страница 16: ...connector and let it exceed of 6 inches in the protection box Tighten the connector screw Connect the wires Position and fix the left and right sides of the 460CFM fan box Use 7 screws for each sides...

Страница 17: ...s Fix the two pipes of 6 inches diameter by using 2 screws per pipe Do not block the anti repression valves operation Fix the thermocouple box L 160 at 30 76cm Plan the thermodisc hole before fixing t...

Страница 18: ...screws Install the retaining collar with 2 bolts and nuts 1 4 X 2 and then tighten the end on the simple pipe Fix it all with 6 screws Screw the fan grid GV460 by using 5 bolts 1 X with locks Screw t...

Страница 19: ...6 inches diameter coated sheet pipe or black steel Fix the 90 degrees elbow only with screws of less than of length because it could affect the good operation of the anti repression valve Fix the ther...

Страница 20: ...20...

Страница 21: ...ommendations you are ready for the lighting 1 Place papers and small wood in the appliance 2 Before lighting be sure that the chimney is warm enough 3 When the fire is well lit gradually add bigger wo...

Страница 22: ...l a smoke return a bad combustion and a counter blow even though you have a combustion or not b Your other appliances such as hearths or other heating appliances release odors heat badly provoke smoke...

Страница 23: ...ing instructions and images 1 Lift up the air entry rod 2 Hook the rod onto the support in order to allow an air supply 3 To measure out the quantity of air into the combustion chamber you have to rot...

Страница 24: ...ance AIR SUPPLY A new air supply can be done by the following ways Indirect method In the case of an appliance not certified for a direct connection with a source of new air supply the new air is brou...

Страница 25: ...hey must always be in good condition Do not alter or modify the air intakes of the appliance in order to get a stronger fire To clean the glasses J A Roby Inc recommends using products sold for this p...

Страница 26: ...TS LIST BRICK PIPES GLASSES BRICKS SUPPORTS DOOR HANDLE APPLIANCE DOOR FAN SEALING CORDS THERMODISC DAMPER MOTOR TRANSFORMATOR THERMOSTAT BUTTERFLY VALVE AIR ENTRY ROD TO ORDER PARTS PLEASE CONTACT YO...

Страница 27: ...by inc will NOT accept any transportation charges The 2nd year J A ROBY Inc assume 50 of repairs according to the above conditions The 3rd year J A ROBY Inc assume 45 of repairs according to the above...