HARDY MANUFACTURING CO., INC (MODEL LC300, LC500 & LC2500)
PAGE 44
8-2
Circulator Maintenance Instructions
Step #
Operation Description
Visual Aids/Comments
Testing/Replacing Pump Cartridge
1
Close the pump inlet and return ball valves to prevent
water flow.
2
Loosen and remove the four(4) 7/16" screws from the
pump motor housing.
3
Gently pull the pump motor housing toward you and turn
so you can view pump impellar.
4
Rotate the pump impellar by hand. If the impellar will
not spin freely then replace the cartridge.
5
Reassemble in reverse order.
!
Hazardous Voltage! Disconnect Power to
Heater prior to performing this
maintenance operation.