background image

User manual

EN

09.07.2020 / 97-9700

www.hwam.com

5530

Содержание 5530

Страница 1: ...User manual EN 09 07 2020 97 9700 www hwam com 5530 ...

Страница 2: ......

Страница 3: ......

Страница 4: ...hese are authorised by regulations made by Welsh Ministers Further information on the requirements of the CleanAirAct can be found here https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements The HWAM 5530 stov...

Страница 5: ...ible combustion as well as a good fuel economy regardless of external conditions such as the type of firewood used the chimney the user s experience and other external circumstances HWAM SmartControlTM consists of the following components Air box the Air box contains a printed circuit board software as well as three motors that control primary secondary and tertiary combus tion air The fresh air s...

Страница 6: ...lso damage your stove and chimney rendering the product warranty void Storage of wood A moisture content of 12 18 is achieved by storing recently felled wood outdoors under a lean to for at least one year preferably 2 years Wood stored indoors has a tendency to become too dry and combust too quickly However it might be advantageous to store fuel for lighting a fire indoors for a few days prior to ...

Страница 7: ...erature drops below the desired level the ember phase will be shortened and the system will activate a re stoking alarm The system will signal that a re stoking is due at the flue gas temperature of 180 C and at 100 C the system will enter standby mode and all dampers will close Should the room temperature be much lower than the desired heat level the control function increases the flue gas temper...

Страница 8: ...re brigade After a fire the stove should be checked by a chimney sweep before use Quick or strong heat Quick or strong heat is obtained by burning many small pieces of wood Maximum firing amount Fuel Maximum amount per hour Wood 2 5 kg Warning Should these limits be exceeded the stove will no longer be covered by the factory guarantee and it may be damaged due to excessive heat The stove has been ...

Страница 9: ...e combustion chamber with an ash suction device Ash can be disposed of through daily refuse collection Be aware that embers in the ash can remain hot up to 24 hours after the fire in the stove has gone out Maintenance Maintenance Regularly check to make sure that seals in the door are complete and soft If not they should be replaced Use only original spare parts The stove should be thoroughly clea...

Страница 10: ...nt which can be bought from your stove dealer Guarantee The guarantee does not cover damage due to insufficient maintenance Operational problems Blackened glass The wood is too damp Only use wood stored for at least 12 months under cover and with a moisture level of approximately 12 18 The doors seals may be not be tight Intermittent firing Allow the stove to heat through properly Smoke in the roo...