background image

Page 5 of 12 pages

hWam

®

 S

marT

C

onTrol

Tm

 

     

               

 

 

 

 

 

 

 

Congratulations on your new wood-burning stove complete with HWAM

®

 SmartControl

TM

HWAM

®

 SmartControl

TM

 is a digital control of the combustion in your new wood-burning stove. The purpose of HWAM

®

 SmartControl

TM

 is to 

control the combustion in an environmentally optimal and economically efficient way, with a view to generating greater user comfort. 

HWAM

®

 SmartControl

TM

 is a patented technology, which electronically adjusts the air supply to the combustion chamber.  Your new wood-burning 

stove continually measures the temperature and the oxygen levels of the combustion. Moreover, it is programmed to supply oxygen to the fire 
through three important air inlets in the right amount, and at the right time and place in the combustion chamber. By downloading a free app for 
your smartphone or tablet, you can use the app among other things: to set the thermostat to the desired room temperature level, choose time for 
night-time reduction and keep your stove updated. The app also gives you current information on burning in the stove. See details in separate manual.

Your new wood-burning stove and HWAM

®

 SmartControl

TM

 will ensure the cleanest possible combustion as well as a good fuel economy, regardless 

of external conditions such as the type of firewood used, the chimney, the user’s experience, and other external circumstances. 

HWAM

®

 SmartControl

TM

 consists of the following components: 

• 

Air box: the  Air box contains a printed circuit board/software, as well as three motors that control primary, secondary, and tertiary combus-
tion air. The fresh-air system can be mounted on the Air box with fresh-air supply from the front or from the bottom. For installation of the 
fresh-air system, see separate instructions. The dimensioned sketches can be found in the separate installation instructions for this stove.

• 

Two sensors: a temperature sensor and an oxygen sensor transmit information from the wood-burning stove to the  Air box.

• 

Room temperature sensor: The room temperature sensor with batteries communicates with the IHS system via a wireless connection. It should 
be placed so it does not have direct radiant heat from the stove. Note that the maximum distance between stove and room temperature 
indicator is about 10 metres. The range is reduced if there are walls or other obstructions between the stove and the room temperature 
indicator. 

• 

Electricity supply: from the  Air box to the nearest wall socket.

• 

App “IHS Smart Control

TM

:The app can be downloaded free from the App Store or Google Play Store. See details in separate manual.

Содержание 5530

Страница 1: ...User manual EN 09 07 2020 97 9700 www hwam com 5530 ...

Страница 2: ......

Страница 3: ......

Страница 4: ...hese are authorised by regulations made by Welsh Ministers Further information on the requirements of the CleanAirAct can be found here https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements The HWAM 5530 stov...

Страница 5: ...ible combustion as well as a good fuel economy regardless of external conditions such as the type of firewood used the chimney the user s experience and other external circumstances HWAM SmartControlTM consists of the following components Air box the Air box contains a printed circuit board software as well as three motors that control primary secondary and tertiary combus tion air The fresh air s...

Страница 6: ...lso damage your stove and chimney rendering the product warranty void Storage of wood A moisture content of 12 18 is achieved by storing recently felled wood outdoors under a lean to for at least one year preferably 2 years Wood stored indoors has a tendency to become too dry and combust too quickly However it might be advantageous to store fuel for lighting a fire indoors for a few days prior to ...

Страница 7: ...erature drops below the desired level the ember phase will be shortened and the system will activate a re stoking alarm The system will signal that a re stoking is due at the flue gas temperature of 180 C and at 100 C the system will enter standby mode and all dampers will close Should the room temperature be much lower than the desired heat level the control function increases the flue gas temper...

Страница 8: ...re brigade After a fire the stove should be checked by a chimney sweep before use Quick or strong heat Quick or strong heat is obtained by burning many small pieces of wood Maximum firing amount Fuel Maximum amount per hour Wood 2 5 kg Warning Should these limits be exceeded the stove will no longer be covered by the factory guarantee and it may be damaged due to excessive heat The stove has been ...

Страница 9: ...e combustion chamber with an ash suction device Ash can be disposed of through daily refuse collection Be aware that embers in the ash can remain hot up to 24 hours after the fire in the stove has gone out Maintenance Maintenance Regularly check to make sure that seals in the door are complete and soft If not they should be replaced Use only original spare parts The stove should be thoroughly clea...

Страница 10: ...nt which can be bought from your stove dealer Guarantee The guarantee does not cover damage due to insufficient maintenance Operational problems Blackened glass The wood is too damp Only use wood stored for at least 12 months under cover and with a moisture level of approximately 12 18 The doors seals may be not be tight Intermittent firing Allow the stove to heat through properly Smoke in the roo...

Страница 11: ...Page 11 of 12 pages ...