background image

WESTFIRE · WF

32

1

dansk ingeniørkunst

 dk:

 

INSTALLATIONS- OG BRUGSVEJLEDNING

WF

32

uk:

 INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

 d:

 

INSTALLATIONS- UND GEBRAUCHSANWEISUNG

Содержание WF32

Страница 1: ...WESTFIRE WF32 1 dansk ingeniørkunst DK INSTALLATIONS OG BRUGSVEJLEDNING WF32 UK INSTALLATION MANUAL AND OPERATING INSTRUCTIONS D INSTALLATIONS UND GEBRAUCHSANWEISUNG ...

Страница 2: ...cm in width and 38 cm in depth The floor on which the wood burning stove is to be installed must be sufficiently strong to carry the weight of the stove The minimum distances to flammable materials are specified on the EN 13240 plaque on the back of the stove There are no rules regarding the minimum distance to non flammable walls but we recommend leaving a gap of at least 10 cm behind the stove t...

Страница 3: ...mply add smaller quantities of wood less often and close the air lever in the centre more than 70 WF 32 is designed for intermittent combustion wood must be added often and the stove is not designed for 24 hour use WF 32 is equipped with a control valve for secondary air designed to ensure a plentiful supply of oxygen during firing When lit the stove will get very hot and due care must therefore b...

Страница 4: ...is is not the case with the smoke plate The Skamol panels will only need to be replaced once they become very worn and are no longer whole or if they crack in several places The air damper and the stove door must be closed in the event of overheating OPERATING PROBLEMS Soot forms on the window The firewood may be too wet or the intake of secondary air may be insufficient The wood burns too quickly...

Отзывы: