34
|
Hampton
®
H27E-11DirectVentFreestandingGasStove
installation
Termination
Cap
Top Adaptor
Existing
Metal
Chimney
System
Aluminum
Flex Pipe
Retro
Connector
Any Simpson
Dura-Vent
black direct vent
pipe plus an
adjustable length
to make a
proper connection.
Converting Class-A
Metal Chimney to
Direct Vent System
Prior to installation and connection of the vent
system to a factory-built chimney, the chimney
must be inspected and thoroughly cleaned by
a qualified service person, such as a certified
chimney sweep or home inspection service.
The direct vent system must not be connected
to a damaged factory-built chimney.
For factory built, zero clearance chimneys
cleanout doors and caps or plugs for cleanout
tee fittings and ash dumps shall be secured
in place and sealed before installing a Direct
Vent system within the chimney.
If the appliance shuts off during operation,
contact a qualified service person to determine
if a negative pressure and/or leaky chimney
condition exists. Do not operate the appliance
until the problem is corrected.
Approved for US Installations Only
The use of an existing chimney as an air intake
is not covered under the ANSI Z21.88-2014, CSA
2.33-2014 test methods and the resulting ITS/
WHI product certification. The code Authority
Having Jurisdiction must be consulted prior to
proceeding with this installation method.
Converting a Factory Built Metal
Chimney
Important: If converting this appliance to a
Factory Built Metal Chimney, the IPI/CPI
switch on the handheld remote control/
transmitter must be turned to CPI (Continu-
ous Pilot Ignition) at all times. This will avoid
nuisance pilot outages during operation
of this appliance. See Remote manual for
setup of this IPI/CPI switch.
1) Removetheexistingchimneycap.
2) Measurethedistancefromthetopendofthe
chimneytothebottomoftheceilingsupport
box,add3"(76mm)tothismeasurement,and
cutasectionofthe4"flexpipetothatlength
(the flex should already be extended to its
nominallength).
4) Passtheflexpipedownthroughthecenterof
thechimneysystem,andcentertheadaptor
onthetopofthechimneypipe.Drillfour1/8"
diameterholesthroughtheadaptorandintothe
chimneytop.Insurethatyouareinfact,drilling
intothemetalonthechimney.Twist-lockthe
TerminationCapontotheAdaptor.(Diagram3
and4).
Diagram 1
Diagram 2
Diagram 3
5) Pulltheflexpipedownthroughtheceiling
supportbox,untilitprotrudesapproximately
3"(76mm).ConnecttheflexpipetotheRetro
Connectorbyslippingitintothe
4-3/4" diameter sleeve on the top side of
theConnector.Use3sheetmetalscrews
toassemblethesetwoparts.
6) Pushtheflexpipebackupintotheceiling
supportbox,centertheRetroConnector,and
attachittothesupportbox,ordecorative
sleevefordoublewallsolidpackedpipe,with
thesheetmetalscrews(supplied).Theholes
in the Retro Connector are pre-punched.
Diagram5.
Diagram 4
Diagram 5
3) Connecttheendoftheflexpipesectiontothe
undersideoftheTopAdaptorusing3sheet
metalscrews.Diagram2.
7) Theconnectionbetweentheapplianceand
theRetroConnectormaybecompletedwith
sectionsofblackdirectventpipe,together
withanadjustablelength.
Содержание H27
Страница 51: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 51 notes...
Страница 56: ...56 Hampton H27E 11 Direct Vent Freestanding Gas Stove warranty...
Страница 57: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 57 notes...
Страница 58: ...58 Hampton H27E 11 Direct Vent Freestanding Gas Stove notes 58...
Страница 59: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 59...