4” x 6-5/8” Rigid Pipe Cross Reference Chart

ComponentsfromdifferentManufacturersmaynotbemixed.NotAllRigidPipecomponentsareavailabledirectlyfromFPI.
Note: OlympiaVentisDVventingisonlyapprovedforcertainmodels.Seelistofapprovedmodelsincross-referencechart.

Description

Simpson

Direct Vent Pro

®

*Selkirk

Direct Temp™

*American Metal
Products®

Amerivent Direct

*Metal-Fab™

Sure Seal

*Security

Secure- Vent®

*ICC Excel 

Direct

*Olympia
Ventis DV***

6" Pipe Length-Galvanized

46DVA-06

4DT-6

N/A

4D6

SV4L6

TC-4DL6

VDV-0406

6" Pipe Length-Black

46DVA-06B

4DT-6B

N/A

4D6B

SV4LB6

TC-4DL6B

VDVB-0406

7" Pipe Length-Galvanized

N/A

N/A

4D7

N/A

N/A

N/A

N/A

7" Pipe Length-Black

N/A

N/A

4D7B

N/A

N/A

N/A

N/A

9" Pipe Length-Galvanized

46DVA-09

4DT-9

N/A

N/A

N/A

TC-4DL9

VDV-0409

9" Pipe Length-Black

46DVA-09B

4DT-9B

N/A

N/A

N/A

TC-4DL9B

VDVB-0409

12" Pipe Length-Galvanized

46DVA-12

4DT-12

4D12

4D12

SV4L12

TC-4DL1

VDV-0412

12" Pipe Length-Black

46DVA-12B

4DT-12B

4D12B

4D12B

SV4LB12

TC-4DL1B

VDVB-0412

18" Pipe Length-Galvanized

46DVA-18

4DT-18

4D18

4D18

SV4LA

TC-4DL18

VDV-0418

18" Pipe Length-Black

46DVA-18B

4DT-18B

4D18B

4D18B

SV4LA

TC-4DL18B

VDVB-0418

24" Pipe Length-Galvanized

46DVA-24

4DT-24

4D24

4D24

SV4L24

TC-4DL2

VDV-0424

24" Pipe Length-Black

46DVA-24B

4DT-24B

4D24B

4D24B

SV4LB24

TC-4DL2B

VDVB-0424

36" Pipe Length-Galvanized

46DVA-36

4DT-36

4D36

4D36

SV4L36

TC-4DL3

VDV-0436

36" Pipe Length-Black

46DVA-36B

4DT-36B

4D36B

4D36B

SV4LB36

TC-4DL3B

VDVCB-0436

48" Pipe Length-Galvanized

46DVA-48

4DT-48

4D48

4D48

SV4L48

TC-4DL4

VDV-0448

48" Pipe Length-Black

46DVA-48B

4DT-48B

4D48B

4D48B

SV4LB48

TC-4DL4B

VDVB-0448

60" Pipe Length-Galvanized

46DVA-60

4DT-60

N/A

N/A

N/A

N/A

N/A

60" Pipe Length-Black

46DVA-60B 

4DT-60B

N/A

N/A

N/A

N/A

N/A

Adjustable Length 3"-10"-Galvanized

N/A

N/A

N/A

4DAL

N/A

TC-4DLT

N/A

Adjustable Length 3"-10"-Black

N/A

N/A

N/A

4DALB

N/A

TC-4DLTB

N/A

Adjustable Length 7"-Galvanized

N/A

N/A

4D7A

N/A

N/A

N/A

N/A

Adjustable Length 7"-Black

N/A

N/A

4D7AB

N/A

N/A

N/A

N/A

Extension Pipe 8-1/2"-Galvanized

46DVA-08A

N/A

N/A

N/A

N/A

N/A

N/A

Extension Pipe 8-1/2"-Black

46DVA-08AB

N/A

N/A

N/A

N/A

N/A

N/A

Adjustable Length 12"-Galvanized

N/A

N/A

4D12A

N/A

SV4LA12

TC-4dLSI

N/A

Adjustable Length 12"-Black

N/A

N/A

4D12A

N/A

SV4LBA12

TC-4dLSIB

N/A

Extension Pipe 16"-Galvanized

46DVA-16A

N/A

N/A

N/A

N/A

N/A

N/A

Extension Pipe 16"-Black

46DVA-16AB

N/A

N/A

N/A

N/A

N/A

N/A

45

º

 Elbow-Galvanized

46DVA-E45

4DT-EL45

4D45L

N/A

N/A

TE-4DE45

VDV-EL0445

45

º

 Elbow-Black

46DVA-E45B

4DT-EL45B

4DT-EL45B

N/A

N/A

TE-4DE45B

VDVB-EL0445

45

º

 Elbow Swivel-Galvanized

See 46DVA-E45

N/A

N/A

4D45L

SV4E45

N/A

N/A

45

º

 Elbow Swivel-Black

See 46DVA-E45B

N/A

N/A

4D45LB

SV4EB45

N/A

N/A

90

º

 Elbow-Galvanized

46DVA-E90

4DT-EL90S

4DT-EL90S

N/A

N/A

TE-4DE90

VDV-EL0445

90

º

 Elbow-Black

46DVA-E90B

4DT-EL90SB

4DT-EL90SB

N/A

SV4EBR90-1

TE-4DE90B

VDVB-EL0445

90

º

 Elbow, Swivel-Galvanized

See 46DVA-E90

N/A

N/A

4D90L

SV4E90-1

N/A

N/A

90

º

 Elbow, Swivel-Black

See 46DVA-E90B

N/A

N/A

4D90LB

SV4EB90-1

N/A

N/A

90

º 

Starter Elbow, Swivel-Galvanized

N/A

N/A

N/A

4D90A

N/A

N/A

N/A

Adaptor*

N/A

N/A

N/A

4D90L

N/A

N/A

VDV-UAA04

4" X 6-5/8" RIGID PIPE CROSS REFERENCE CHART

Components from different Manufacturers may not be mixed.  Not all rigid pipe components are available directly from Regency.
Note: Olympia Ventis DV venting is only approved for certain models. See list of approved models in cross-reference chart.

Ceiling Support

N/A

4DT-CS

4DSP

4DFSP

SV4SD

TM4-RDS

VDV-SCR04

Cathedral Support Box

46DVA-CS

4DT-CSS

4DRSB

4DRS

SV4CSB

TM4-SDS

VDV-CSS04

Wall Support/Band

46DVA-WS

4DT-WS/B

4DWS

4DWS

SV4BM

TM-SWS

VDV-WS04

Offset Support

46DVA-ES

 

4DT-OS

N/A

N/A

SV4SU

TM-SOS

N/A

Wall Thimble-Black

46DVA-WT

4DT-WT

4DWT

4DWT

SV4RSM

N/A

VDV-WPT04

Wall Thimble Cover/Ceiling Support

46DVA-DC

 

N/A

N/A

N/A

SV4PF

N/A

N/A

Firestop Spacer

46DVA-FS

4DT-FS

4DFSP

4DFS

SV4BF

TM-4CS

VDV-FS04

Trim Plate-Black

N/A

4DT-TP

4DFPB

4DcP

SV4LA

TM-4TP

VDV-WTC04

* Not available from Regency

Содержание H27

Страница 1: ...ppliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas...

Страница 2: ...has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model H27E 11 has been approved byWarnock Hersey Intertek for both safety and efficiency...

Страница 3: ...tilation Air 15 Accent Light Bulb Install 15 Optional Fan Installation 16 Glass Front Removal installation 17 Venting Introduction 18 Installation Precautions 18 Safety Precautions for the Installer 1...

Страница 4: ...SALE 4001172 Listed VENTED GAS FIREPLACE HEATER FOYER AU GAZ VACUATION Certified to Certifi CSA 2 17 2017 ANSI Z21 88 2017 CSA 2 33 2017 This appliance must be installed in accordance with local codes...

Страница 5: ...above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in s...

Страница 6: ...e dimensions Unit Dimensions with Vertical Venting Unit Dimensions with Horizontal Venting 452 mm 17 13 16 452 mm ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY...

Страница 7: ...nsult the building authority having jurisdiction to determine the need for a permit prior to starting the installation Note Failure to follow the instructions could cause a malfunction of the heater w...

Страница 8: ...ystem will need to be reset as follows a Wait 5 minutes turn the system off by pressing the ON OFF button on the remote b After approximately 2 seconds turn on ON OFF switch or press ON OFF button if...

Страница 9: ...iellement Faites inspecter l appareil par un technicien qualifi et remplacez tout l ment du syst me de contr le ou de commande qui a t plong dans l eau This appliance must be installed in accordance w...

Страница 10: ...simple button layout and informative LCD display Fig 1 A Mode Key is provided to index between the features and a Thermostat Key is used to turn on off or index through Thermostat functions Fig 1 2 Ad...

Страница 11: ...e flame height by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is...

Страница 12: ...roflame system The fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adj...

Страница 13: ...IPI to a continuous pilot ignition system CPI by using remote control as noted above The benefits of having as CPI are as follows Keeps venting primed for trouble free start up under colder weather c...

Страница 14: ...mperative that control compartments and circulating air passageways of the appliance be kept clean and free from excessive lint from carpeting 4 See general construction and assembly in structions The...

Страница 15: ...wall if installing the blower option so the fan can be easily installed and or serviced Locating Your Gas Stove When selecting a location for your stove ensure that the clearances listed above are met...

Страница 16: ...ck of the left side access panel 7 Loosen the 2 bolts on fan assembly and slide the fan into the slots provided on the unit 8 Once the fan assembly is fitted into the assigned slots tighten the bolts...

Страница 17: ...up light assembly bracket and place light assembly out of the way 4 Remove 2 bolts from underside of the cast faceplate from locations shown below 5 Remove 2 bolts from the bracket securing the cast s...

Страница 18: ...y Co Axial system The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingtheneedtouseheated room air...

Страница 19: ...of center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air i...

Страница 20: ...Black N A N A N A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A...

Страница 21: ...tional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser...

Страница 22: ...t Direct Vent American Metal Products Ameri Vent Direct Vent Security Secure Vent Selkirk Direct Temp and ICC Excel AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd Du...

Страница 23: ...45o elbows If the vent is ENCLOSED in a chase min size 9 x 9 maintain a 1 1 4 clearance to combustibles May be installed in Manufactured Mobile Homes after first sale Horizontal Terminations for All V...

Страница 24: ...Min 6 Max D 5 Min 7 Max E 6 Min 8 Max Lengths do not include elbow indicated Vent restrictor position A fully open refer to the Vent Restrictor Position section One 90o elbow Two 45o elbow Option H V...

Страница 25: ...feet total horizontal Please note min 1 foot be tween90o elbowsisrequired Vent restrictor position A fully open refer to the Vent Restrictor Position section Lengths do not include elbow indicated Opt...

Страница 26: ...x running the full length of the chimney See the Venting Arrangements chart below for minimum and maximum flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is u...

Страница 27: ...both the starter collar and the 90o elbow Crimped section of rigid pipe seats into the 90o elbow Only cut the uncrimped side of pipe Dismantle all pipe sections including vent terminal 2 Assembleatri...

Страница 28: ...hardening mastic should be run around both the termination and vinyl sidingstandofftopreventwaterfromentering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia flex liner o...

Страница 29: ...the proper length of vent pipe for your particular requirements Determine the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the wall thickness Be...

Страница 30: ...o horizontal type installations Warning Alwaysmaintainrequired clearances air spaces to nearby combustibles to prevent a fire hazard Do not fill air spaces with insulation Theminimumclearancerequireme...

Страница 31: ...d is constructed of non combustible material i e masonry block or concrete a 7 diameter hole is acceptable a The horizontal run of vent should have a 1 4 inch rise for every 1 foot of run towards the...

Страница 32: ...e hidden on the final installation NOTE For best results and optimum performance with each approved vent ing system it is highly recommended to apply Mill Pac sealant supplied to everyinnerpipeconnect...

Страница 33: ...result in drafting or performance issues not covered under warranty 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Round SupportBo...

Страница 34: ...I switch on the handheld remote control transmittermustbeturnedtoCPI Continu ousPilotIgnition atalltimes Thiswillavoid nuisance pilot outages during operation of this appliance See Remote manual for s...

Страница 35: ...re Natural Gas min 5 0 w c Propane min 12 0 w c Manifold Pressure Natural Gas 3 5 w c Propane 10 w c 8 Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails slide...

Страница 36: ...ve 1 Make sure the valve is in the OFF position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pres sure tap s...

Страница 37: ...pilot cap to expose the pilot orifice 6 Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap 7 Remove burner orifice with a 1 2 wrench a...

Страница 38: ...dia grams Ifthelogsarebrokendonotusetheunituntiltheyare replaced Broken logs can interfere with the pilot operation The gas log kit Part 350 930 contains the following a Rear Log b Left Side Front Lo...

Страница 39: ...theburner in and around where the embers are placed Avoid stacking platinum embers 6 Place the center cross log D so it rests in the notch located on the top of the rear log position as shown below Lo...

Страница 40: ...Anyalterationtotheproductthatcausessooting orcarboningthatresultsindamagetotheexterior faciaisnottheresponsibilityofthemanufacturer Back Up Battery In the event of a power outage the unit may be oper...

Страница 41: ...ch a hot surface and are away from sharp edges WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and sho...

Страница 42: ...42 Hampton H27E 11 Direct Vent Freestanding Gas Stove operating instructions Wiring Diagram With Thermostat RESET SWITCH Thermostat Optional Millivolt...

Страница 43: ...lean the glass while it is hot DONOTBURNTHEAPPLIANCEWITH OUT THE GLASS FRONT IN PLACE starting operatingtheappliance pleasereadthe remote control operating instructions packed with remote control to u...

Страница 44: ...system will need to be reset as follows a Wait 5 minutes turn the system off by pressing the ON OFF button on the remote b After approximately 2 seconds turn on ON OFF switch or press ON OFF button i...

Страница 45: ...u m me partiellement Faites inspecter l appareil par un technicien qualifi et remplacez tout l ment du syst me de contr le ou de commande qui a t plong dans l eau This appliance must be installed in a...

Страница 46: ...ED TO THE HAZARDS OF HIGH SURFACE TEMPERATUREANDSHOULDSTAY AWAYTOAVOIDBURNSORCLOTH ING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPER VISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE 8 Each ti...

Страница 47: ...chanicalsupportssuch as Wall Straps or plumbers tape for rigidity 5 Verify proper operation after servicing Log Replacement Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and allow the...

Страница 48: ...6 Lift off the Cast Top and remove the Cast Front and glass door see detailed instruction in this manual 7 Carefully move the light bracket out of the way 8 Carefully remove the logs and embers 9 Remo...

Страница 49: ...Part Description Part Description 350 004 Baffle Plate for Firebox 350 022 Casting Mount Bracket Fan Air Divider 50 W260260 Top Relief Frame Gasket 51 942 117 Top Relief Frame 52 W260280 Top Relief Pl...

Страница 50: ...Socket Assembly 910 997 Halogen Light Bulb 120 Volt 20 Watt JCD Bi Pin Gy6 35 910 157 P Blower Motor Only with Squirrel Cage 911 027 Battery Holder W 9V Snap in 4 AA Batteries 911 257 2 Pin Wiring Har...

Страница 51: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 51 notes...

Страница 52: ...Control Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Cryst...

Страница 53: ...ndrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of...

Страница 54: ...de the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the autho...

Страница 55: ...low in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Produc...

Страница 56: ...56 Hampton H27E 11 Direct Vent Freestanding Gas Stove warranty...

Страница 57: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 57 notes...

Страница 58: ...58 Hampton H27E 11 Direct Vent Freestanding Gas Stove notes 58...

Страница 59: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 59...

Страница 60: ...ler Name Address _______________________________________________ ___________________________________________________________________ Installer _________________________________________________________...

Отзывы: