DV Stove Horizontal Vent Kit (#946-116 & #946-216) Installation
Reviewthefollowingsequenceofinstructions
whicharetypicalofmostinstallations.These-
quencemayvarydependingonwallthickness.
See the "Exterior Vent Terminal Locations"
section for vent location and clearance
dimensions, and "Vent Restrictor Position"
section to set the Vent Restrictor to the
correct position.
1) Settheunitinitsdesiredlocation.Check
todetermineifwallstudswillbeintheway
oftheventingsystem,adjustlocationuntil
all clearances are met and there are no
obstructions.
Note: A 1-1/2"(38mm) clearance around
the outer pipe must be main-
tained except that only a 1"
(25mm) clearance is needed at
the termination end.
IMPORTANT:
Do not locate termination hood where
excessive snow or ice buildup may oc-
cur. Be sure to check vent termination
area after snow falls, and clear to prevent
accidental blockage of venting system.
When using snow blowers, make sure
snow is not directed towards vent ter-
mination area.
b) Installwallthimblesonbothinteriorand
exteriorwallwith4woodscrews(#8x
1")perthimble.
c)
Attachthe2pieceadjustablepipe
sectiontotheventterminalandslide
intopositionfromtheexterior.
The larg-
er diameter end of the adjustable pipe
goes to the vent terminal.
d) Installthe90
o
elbowontotheadjus
ablepipetodeterminethevertical
centerline.
Note: if the centerline cannot be met,
the adjustable sections will have to
be cut.
e)
Cutthe4ft.sectionofrigidpipeto
length.Attachthe45
o
elbowtotherigid
pipe,andensurethatthepipelength
whencut(withthe45
o
elbow)willseat
ontoboththestartercollarandthe90
o
elbow.
Crimped section of rigid pipe
seats into the 90
o
elbow. Only cut the
uncrimped side of pipe.
Dismantleallpipesectionsincluding
ventterminal.
2) Assemblea
trial fittodeterminethevertical
centerlinefortheventtermination.
a) Cuta9-1/2"x9-1/2"(241mmx241mm)
squareholeonboththeinteriorandexterior
wall.
Adapter
Trim Collar
4" ID Liner
Spacer
Spring
Thimble
Cover
Termination Cap
(Part# 946-523/P)
AstroCap
Wall Thimble
(required for
combustible walls)
Adjustable Pipe
Length 13-1/2" - 24",
2 pieces
4 ft. Pipe Length
with Kit # 946-216
or 2 ft. Pipe Length with
Kit # 946-116
Trim
Collar
DV Stove Horizontal Vent Kit
DV2ft.StoveVentKit(Part#946-116)andDV4ft.StoveVentKit(946-216)includesallthepartsneeded
toinstalltheH27DirectVentunitwithminimumhorizontalandverticalventdimensions.Forinstallations
thatrequirelongerverticaland/orhorizontalventsusetheDura-Ventsystemasshowninthe"Dura-Vent
TerminationKit"and"Dura-VentVentingComponents"sections.
Qty.
Description
1) 1 RigidPipeSection(Kit#946-116:2ft.(1.2m)length,
Kit#946-216:4ft.(1.2m)length,6-1/2"(165mm)
insidediameter
2) 1 FlexLiner,compressedaluminium2plyliner,4"(102mm)
insidediameter
3) 4 springspacers
4) 1 90deg.Elbow
5) 1 Adjustablepipesection13-1/2"to24"(343mmx610mm),2pcs.
6) 1 ThimbleCover
7) 1 WallThimble(2pcs.)
8) 1 Adapter
9) 1 AstroCapTerminationCap
10)2 TrimCollars
11)1 TubeofMill-Pac,hightemperaturesealant
12)12 Screws,#8x1/2"Selftapping,StainlessSteel
13)14 Screws,#8x1/2"Selftapping,Black
14)4 Screws#8x1-1/2"DrillPoint,Black
15)4 Screws#8x1-1/2"DrillPoint,StainlessSteel
16)8 Woodscrews#8x1"
Note:
a) Liner sections should be continu-
ous without any joints or seams.
b) This is an approved system, there-
fore components in this system
must not be substituted for any
other manufacturer's products.
Содержание H27
Страница 51: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 51 notes...
Страница 56: ...56 Hampton H27E 11 Direct Vent Freestanding Gas Stove warranty...
Страница 57: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 57 notes...
Страница 58: ...58 Hampton H27E 11 Direct Vent Freestanding Gas Stove notes 58...
Страница 59: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 59...